WAPWALLOPEN, PA —
OSHA Inspection: CARL BALLIET LOGGING AND LUMBER, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CARL BALLIET LOGGING AND LUMBER, INC. in 556 LILY LAKE ROAD, WAPWALLOPEN, PA 18660 (NAICS 321999). OSHA activity number 345608582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARL BALLIET LOGGING AND LUMBER, INC.
- Site address
- 556 LILY LAKE ROAD
- City
- WAPWALLOPEN
- State
- PA
- ZIP
- 18660
- Mailing
- 556 LILY LAKE ROAD, WAPWALLOPEN, PA 18660
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 10, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $4,351 · Current $2,500 Reduced
E200
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: a) Band saw area: The top of a wall mounted electrical switch box were not kept free from accumulations of combustible wood dust, on or about, October 29, 2021. b) Exhaust blower area: The tops of two wall mounted electrical switch boxes were not kept free from accumulations of combustible wood dust which created a fire and explosion hazard, on or about, October 29, 2021. d) Band saw exhaust blower area: The motor housing and cooling fins of the band saw exhaust blower motor were not kept free of accumulations of combustible wood dust which created a fire and explosion hazard, on or about October 29, 2021. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
- — J (S) $2500
- — C (S) $4351
- — Z (S) $4351
1910.22 A02
- Issued
- Feb 10, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $0 · Current $0
E200
General-duty citation text
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition: a) Band saw area: The floor was not kept free from an accumulation of combustible wood dust which created a fire and explosion hazard, on or about October 29, 2021. b) Exhaust blower area: The floor was not kept free from an accumulation of combustible wood dust which created a fire and explosion hazard, on or about October 29, 2021. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.265 C20 I
- Issued
- Feb 10, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
E200
General-duty citation text
29 CFR 1910.265(c)(20)(i): Blower collecting and exhaust systems were not maintained in accordance with American National Standards Z33.1-1961 which is incorporated by reference as specified in �1910.6: a) The Wood-Mizer LT300 head saw: The exhaust duct for the Wood-Mizer LT300 head saw had a hose with a collapsed section, on or about October 29, 2021. b) The Challenger CH100 grinder: The Challenger CH100 grinder ductwork lacked structural integrity with poor patchwork and was not properly fastened to the intake of the blower housing, on or about October 29, 2021. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
- — J (S) $0
- — C (S) $4351
- — Z (S) $4351
1910.307 C
- Issued
- Feb 10, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $4,351 · Current $2,500 Reduced
E200
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: b) Exhaust blower: The Cutler-Hammer switch box had openings on the front cover which allowed wood dust to enter the interior and was not approved for a high dust location, on or about October 29, 2021. d) Exhaust motor for the band saw: The electrical motor had heavy accumulations of wood dust on its casing and cooling fins which interfered with the cooling of the motor, on or about October 29, 2021. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
- — J (S) $2500
- — C (S) $4351
- — Z (S) $4351
More inspections at Carl Balliet Logging and Lumber, INC.
View Carl Balliet Logging and Lumber, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345608582.