Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ULTRATEK, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ULTRATEK, LLC in 1 CASTINE STREET, WORCESTER, MA 01601 (NAICS 561730). OSHA activity number 345608731.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ultratek, LLC — free Get an email when a new federal OSHA severe-injury report for Ultratek, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ULTRATEK, LLC
Site address
1 CASTINE STREET
City
WORCESTER
State
MA
ZIP
01601
Mailing
178 DUGG HILL ROAD, WOODSTOCK, CT 06281
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
5
Ownership type
A

2 citations on file for this inspection.

1910.180 H01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 10, 2022
Abate by
Apr 5, 2022
Penalty
Initial $4,351 · Current $2,175 Reduced
29 CFR  1910.180(h)(1)(i): No crane shall be loaded beyond the rated load, except for test purposes as provided in paragraph (e) of this section.  a) Jobsite 1 Castine Street, Worcester, MA on or about October 28, 2021 and at times prior, the employer did not ensure lifted loads were kept within the cranes safe working load chart exposing  employees to hazards resulting from failure and or collapse of the crane, its load and or its boom structure.  On October 28, 2021 and at times prior,  an employee operating a National Crane model NBT 45-1 did not follow the manufacturers safety instructions or follow the crane manufacturers Load Charts and proceeded to lifted loads in excess of the cranes rated capacities, ultimately resulting in the cranes collapse and loss of control of the suspended load.
Recent events (2)
  • — I (S) $2175
  • — Z (S) $4351

1910.180 H03 IX

Deleted Serious Gravity 10 27 instances 5 exposed
Issued
Mar 10, 2022
Abate by
Apr 5, 2022
Penalty
Initial $4,351 · Current $0 Reduced
29 CFR  1910.180(h)(3)(ix)(c): Outriggers shall be used when the load to be handled at that particular radius exceeds the rated load without outriggers as given by the manufacturer for that crane. Where floats are used they shall be securely attached to the outriggers. Wood blocks used to support outriggers shall be of sufficient width and length to prevent shifting or toppling under load.    a)  Jobsite 1 Castine Street, Worcester, MA on or about October 28, 2021, The employer had not ensured that outrigger floats for the  National Crane model NBT 45-1 were securely attached to the outriggers and that wood blocks used were of sufficient width and length to prevent shifting or toppling under load.  The city the jobsite was located in had received several inches of rain the day before the accident and the crane was setup on a grass covered lawn.  The outriggers were deployed with the floats but no or insufficient wood blocks were utilized to under the front passenger outrigger to ensure the setup area was capable of supporting the intended load.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345608731.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.