Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BORGWARNER TRANSMISSION PRODUCTS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BORGWARNER TRANSMISSION PRODUCTS, LLC in 700 S. 25TH AVE., BELLWOOD, IL 60104 (NAICS 336350). OSHA activity number 345612402.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Borgwarner Transmission Products, LLC — free Get an email when a new federal OSHA severe-injury report for Borgwarner Transmission Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
700 S. 25TH AVE.
City
BELLWOOD
State
IL
ZIP
60104
Mailing
700 S. 25TH AVE., BELLWOOD, IL 60104
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336350
Employees
575
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Mar 21, 2022
Abate by
May 1, 2023
Penalty
Initial $7,748 · Current $7,748
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6): 1.	Turn off and shut down power to the machinery, 2.	Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), 3.	Affix lockout/tagout devices to each energy isolating device, 4.	Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work:  a) Steel Blanking Department - On or about November 1, 2021, employees were exposed to machine hazards associated with moving parts while performing servicing tasks on the Steel Blanking Presses 45 and 10, such as performing setups and change overs, clearing jams, and adjusting the clamps on the die. The employer did not implement energy control application steps as the machine was not shut down and deenergized to perform the adjustments [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (5)
  • — P (O) $7748
  • — P (O) $7748
  • — P (O) $7748

1910.147 F03 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2022
Abate by
Jun 1, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance was performed by a crew, craft, department or other group,  the employer did not ensure that employee(s) utilized a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device:  a) Steel Blanking Department- On or about November 1, 2021, the employer did not require that each employee, working in a team or group performing servicing and maintenance on equipment, affix lockout/tagout devices to equipment prior to performing the work, such as adjusting clamps on Steel Blanking Press 45.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Borgwarner Transmission Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345612402.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.