On , OSHA opened a federal Agency safety inspection of FORD MOTOR COMPANY in 1155 BIBLE RD., LIMA, OH 45801 (NAICS 336310). OSHA activity number 345620959.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FORD MOTOR COMPANY
- Site address
- 1155 BIBLE RD.
- City
- LIMA
- State
- OH
- ZIP
- 45801
- Mailing
- 1155 BIBLE RD., LIMA, OH 45801
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336310
- Employees
- 1500
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D03
- Issued
- Apr 12, 2022
- Abate by
- Apr 28, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a) Ford Motor Company on or about November 03, 2021, at the address of 1155 Bible Rd. Lima, OH: The employer did not ensure that energy isolating procedures for the 68-70 Gantry were implemented prior to employee performance of service activities on the interconnected 70.1 Grob CNC Machine. A maintenance employee performing these tasks on the CNC machine while in the path of travel of the energized Gantry was exposed to struck-by hazards. The employer's established energy control procedure [required under 29 CFR 1910.147(d)] was not adequately utilized before the employee began the aforementioned work task while positioned in the interconnected gantry's path of travel.
Recent events (3)
- — F (S) $14502
- — C (S) $14502
- — Z (S) $14502
More inspections at Ford Motor Company