FORT BUCHANAN, PR —
OSHA Inspection: DEPARTMENT OF DEFENSE EDUCATION ACTIVITY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DEPARTMENT OF DEFENSE EDUCATION ACTIVITY in 1081 CHRISMAN RD, FORT BUCHANAN, PR 00934 (NAICS 611110). OSHA activity number 345623938.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEPARTMENT OF DEFENSE EDUCATION ACTIVITY
- Site address
- 1081 CHRISMAN RD
- City
- FORT BUCHANAN
- State
- PR
- ZIP
- 00934
- Mailing
- 700 WESTPARK DRIVE, 2ND FLOOR, PEACHTREE CITY, GA 30269
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 611110
- Employees
- 59
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.28 B01 I A
- Issued
- Jan 7, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(1)(i)(A): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling by a standard guardrail system. (a) On or about November 3, 2021, at DoDEA, Antilles Middle school - the employer did not ensure that each employee on a walking-working surface with an unprotected edge less than 4 feet (1.2 m) above a lower level was protected from falling by a standard guardrail system, exposing employees to a fall hazard. NOTE: Certification and abatement documentation must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1910.147 C01
- Issued
- Jan 7, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training, and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) On or about November 3, 2021, at DoDEA, Antilles Middle school - the employer did not develop, document, and utilize an energy control procedure (lockout/tag-out program), conduct periodic audits, and did not provide training on the energy control procedures to ensure that employees understood all required elements of the procedure and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees performing servicing and repair work on a machine or equipment such as, but not limited to exhaust fans, exposing employees to electrical shock hazard. NOTE: Certification and abatement documentation must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 7, 2022
- Abate by
- Jan 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. (a) On or about November 3, 2021, at DoDEA, Antilles Middle school, Fort Buchanan - the employer did not provide training on energy control procedures and the safe application, usage, and removal of the energy control exposing, employees to electrical shock hazard. NOTE: Certification and abatement documentation must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (1)
- — Z (S) $0
More inspections at Department of Defense Education Activity
View Department of Defense Education Activity's full OSHA safety record →
More inspections in this industry (NAICS 611110)
More inspections in PR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345623938.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.