OSHA Inspection: MANSFIELD ENGINEERED COMPONENTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MANSFIELD ENGINEERED COMPONENTS, INC. in 1776 HARRINGTON MEMORIAL RD., MANSFIELD, OH 44903 (NAICS 332510). OSHA activity number 345629778.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mansfield Engineered Components, INC. — free Get an email when a new federal OSHA severe-injury report for Mansfield Engineered Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1776 HARRINGTON MEMORIAL RD.
City
MANSFIELD
State
OH
ZIP
44903
Mailing
1776 HARRINGTON MEMORIAL RD., MANSFIELD, OH 44903
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
220
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 33 exposed
Issued
Jan 28, 2022
Abate by
Mar 9, 2022
Penalty
Initial $13,052 · Current $6,526 Reduced
29 CFR  1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  Mansfield Engineered Components, Inc. - Mansfield, Ohio: On or about November 1, 2021, the employer did not ensure that employees who service and maintain the #R-28 Milford Rivet & Machine Co. riveter (model S413; s/n 1342) were trained in the skills required for the safe application, usage, and removal of energy controls. Employees that unjam the machine were not trained to isolate and render safe the residual energy of the flywheel.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $6526
  • — Z (S) $13052

1910.147 D

Serious Gravity 10 1 instance 33 exposed
Issued
Jan 28, 2022
Abate by
Mar 9, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  Mansfield Engineered Components, Inc. - Mansfield, Ohio: On or about November 1, 2021, the employer did not ensure that the #R-28 Milford Rivet & Machine Co. riveter (model S413; s/n 1342) was shut down and energy control steps were implemented to control the mechanical energy of the equipment's flywheel prior to servicing tasks.  Employees who unjammed the riveter were exposed to injury from rotating parts and nip points.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Other-than-serious 1 instance 33 exposed
Issued
Jan 28, 2022
Abate by
Mar 9, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  Mansfield Engineered Components, Inc. - Mansfield, Ohio: On or about November 1, 2021, the employer did not ensure energy control procedures for the #R-28 Milford Rivet & Machine Co. riveter (model S413; s/n 1342) identified specific steps to follow to render safe the residual energy of the flywheel.  Employees that unjam the machine were exposed to rotating part and nip-point hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0