FARMINGTON, CT —
OSHA Inspection: PAUL DAVIS RESTORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAUL DAVIS RESTORATION in 244-248 MAIN STREET, FARMINGTON, CT 06030 (NAICS 238130). OSHA activity number 345630313.
Where did this inspection happen?
- Establishment
- PAUL DAVIS RESTORATION
- Site address
- 244-248 MAIN STREET
- City
- FARMINGTON
- State
- CT
- ZIP
- 06030
- Mailing
- 21 ANDOVER DRIVE SUITE C, WEST HARTFORD, CT 06110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 9
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B04 I
- Issued
- Penalty
- Initial $4096.00 · Current $2867.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. On or about November 10, 2021 employees at the 244 Main Street, Farmington, CT construction project were exposed to falls while engaged in framing activities without fall protection in the following locations: A) Employees were exposed to approximately 10' falls through an unprotected hole opening in the center of the newly constructed floor deck. B) Employees were exposed to approximately 10' falls through an unprotected hole opening of a current stairwell opening.
Recent events (2)
- — I (S) $2867.2
- — Z (S) $4096
More inspections at PAUL DAVIS RESTORATION
VANCOUVER, WA—2013-10-09 00:00:00
PAUL DAVIS RESTORATION
VANCOUVER, WA—2012-10-26 00:00:00
PAUL DAVIS RESTORATION
MAPLE HEIGHTS, OH—2009-10-28 00:00:00
PAUL DAVIS RESTORATION
DENVER, CO—2009-06-29 00:00:00
PAUL DAVIS RESTORATION
CHEHALIS, WA—2008-08-07 00:00:00
PAUL DAVIS RESTORATION
View PAUL DAVIS RESTORATION's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345630313.