Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J ROBERTO CHAVEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J ROBERTO CHAVEZ in 527 W. ERWIN, TYLER, TX 75704 (NAICS 238140). OSHA activity number 345631444.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J Roberto Chavez — free Get an email when a new federal OSHA severe-injury report for J Roberto Chavez is published. One employer, no account, unsubscribe in one click.
Establishment
J ROBERTO CHAVEZ
Site address
527 W. ERWIN
City
TYLER
State
TX
ZIP
75704
Mailing
4351 TEXAS HWY. 110, TYLER, TX 75704
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.300 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 20, 2022
Abate by
May 16, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.300(b)(1):Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  (a) On or about November  9, 2021 at the site employees were exposed to amputation hazards when operating a Dewalt  masonry saw without a blade guard.
Recent events (1)
  • — Z (S) $4351

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2022
Abate by
May 16, 2022
Penalty
Initial $3,729 · Current $3,729
29 CFR  1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) On or about November  9, 2021 at the site employees were exposed to electrical shock hazards when a flexible cord with exposed coated conductors was used at the site.
Recent events (1)
  • — Z (S) $3729

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345631444.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.