Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEW LEAF INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NEW LEAF INC in NAS WHIDBEY, BUILDING 2546 JANITORIAL BUILDING, OAK HARBOR, WA 98277 (NAICS 624310). OSHA activity number 345636765.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NEW Leaf INC — free Get an email when a new federal OSHA severe-injury report for NEW Leaf INC is published. One employer, no account, unsubscribe in one click.
Establishment
NEW LEAF INC
Site address
NAS WHIDBEY, BUILDING 2546 JANITORIAL BUILDING
City
OAK HARBOR
State
WA
ZIP
98277
Mailing
PO BOX 943, OAK HARBOR, WA 98277
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
624310
Employees
26
Ownership type
A

8 citations on file for this inspection.

1910.132 D01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 10, 2022
Abate by
Mar 9, 2022
Penalty
Initial $5,548 · Current $2,774 Reduced
29 CFR  1910.132(d)(1)(i):The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:  a) Jobsite, where face or eye protection such as, splash goggles, were not provided for employee use while pouring BETCO Extreme, a corrosive, into mop buckets containing water.
Recent events (2)
  • — I (S) $2774
  • — Z (S) $5548

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 10, 2022
Abate by
Mar 9, 2022
Penalty
Initial $6,657 · Current $3,329 Reduced
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Building 994, where employees poured BETCO Extreme, a corrosive, from a 5 gallon container into mop buckets containing water.
Recent events (2)
  • — I (S) $3328.5
  • — Z (S) $6657

1910.134 D01 III

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Penalty
Initial $3,328 · Current $1,664 Reduced
29 CFR  1910.134(d)(1)(iii):The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  a) Jobsite, where the employer permitted employees to use their own full-face respirators, and provided Ranksing 6200 half-face respirators and Fangtian FT-N040 N95 (dust masks) respirators to employees for use while mixing and applying BETCO Extreme floor stripper. Hazard: Improper selection of respiratory protection without first determining the airborne concentration BETCO Extreme.
Recent events (2)
  • — I (S) $1664
  • — Z (S) $3328

1910.134 D01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(i):Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:  a) Jobsite, where the employer provided Fangtian FT-N040 N95 (dust masks) respirators for use while mixing chemicals such as, the BETCO Extreme liquid floor stripper. Hazard: N95 being saturated with a corrosive chemical and coming into contact with skin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(ii):The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:  a) Jobsite, where the employer provided Ranksing 6200 half-face respirators to employees for use while mixing and stripping floors with BETCO Extreme.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Abate by
Mar 9, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(i):The employer did not determine if the voluntary use of a respirator did not in itself create a hazard:  a) Jobsite, where the employer permitted employees to use their own full-face respirators, and provided Ranksing 6200 half-face respirators and Fangtian FT-N040 N95 (dust mask) respirators to employees for use while mixing and applying BETCO Extreme floor stripper. Hazard: An employee's health being jeopardized by the wearing of a respirator (e.g., employee has a cardiac and/or pulmonary disorder that could be aggravated by respirator use), or the wearing of a dirty respirator that could cause dermatitis or ingestion of a hazardous chemical.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Abate by
Mar 9, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  a) Jobsite, where the employer permitted employees to use their own full-face respirators, and provided Ranksing 6200 half-face respirators to employees for use while mixing and applying BETCO Extreme floor stripper.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2022
Abate by
Mar 9, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Jobsite, where the employer permitted employees to use their own full-face respirators, and provided Ranksing 6200 half-face respirators and Fangtian FT-N040 N95 (dust mask) respirators to employees for use while mixing and applying BETCO Extreme floor stripper.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View NEW Leaf INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345636765.