Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EXTREME ROOFING AND SIDING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXTREME ROOFING AND SIDING LLC in 1111 MILES COURT LOT #46, CHELTENHAM, PA 19012 (NAICS 238160). OSHA activity number 345637771.

Watch Extreme Roofing AND Siding LLC — free Get an email when a new federal OSHA severe-injury report for Extreme Roofing AND Siding LLC is published. One employer, no account, unsubscribe in one click.
Site address
1111 MILES COURT LOT #46
City
CHELTENHAM
State
PA
ZIP
19012
Mailing
1254 GENESEE STREET APT. 1, TRENTON, NJ 08611
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $4351.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) 1111 Miles Court, Cheltenham, PA 19012, Roof: On or about November 9, 2021, employees using a personal fall arrest system (harness & lanyard ) were not tied off at all times when performing roofing activities. Employees were exposed to fall hazards of 20 feet to the ground below.
Recent events (1)
  • — Z (S) $4351

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2486.00 · Current $2486.00
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) 1111 Miles Court, Cheltenham, PA 19012, Roof: On or about November 9, 2021, employees used a portable, 24-foot aluminum extension ladder to access a roof, but the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface.
Recent events (1)
  • — Z (S) $2486

1926.1053 B16

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired  (a) 1111 Miles Court, Cheltenham, PA 19012, Roof: On or about November 9, 2021 employees used a 24-foot Louisville extension ladder to access the roof of a two-level residential structure, however, the ladder was damaged with a bent rung.
Recent events (1)
  • — Z (S) $0

View EXTREME ROOFING AND SIDING LLC's full OSHA safety record →