Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERCONTINENTAL SERVICES OF DELAWARE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INTERCONTINENTAL SERVICES OF DELAWARE, LLC in 700 NEW CASTLE AVENUE 700 NEW CASTLE AVE, WILMINGTON, DE 19801 (NAICS 493110). OSHA activity number 345638860.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intercontinental Services of Delaware, LLC — free Get an email when a new federal OSHA severe-injury report for Intercontinental Services of Delaware, LLC is published. One employer, no account, unsubscribe in one click.
Site address
700 NEW CASTLE AVENUE 700 NEW CASTLE AVE
City
WILMINGTON
State
DE
ZIP
19801
Mailing
1020 CHRISTIANA AVENUE, WILMINGTON, DE 19801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
30
Ownership type
A

7 citations on file for this inspection.

1910.22 A03

Serious Gravity 10 1 instance 20 exposed
Issued
May 12, 2022
Penalty
Initial $11,167 · Current $7,817 Reduced
29 CFR  1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.  a) 700 New Castle Ave Wilmington, DE 19801: On or about November 16, 2022, the employer failed to ensure that all risers and treads that connect one level with another were free of corrosion and structurally sufficient to withstand the  weight of employees traveling to and from their workplace.
Recent events (2)
  • — I (S) $7816.9
  • — Z (S) $11167

1910.22 D01

Serious Gravity 10 1 instance 20 exposed
Issued
May 12, 2022
Penalty
Initial $11,167 · Current $0 Reduced
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition  a) 700 New Castle Ave Wilmington, De. 19801: On or about November 16, 2022, the employer failed to ensure that the stairway leading into the warehouse building was free of walking /working surface hazards. The failure of frequent and regular inspection resulted in the stairway being corroded and structurally unstable, resulting in a unsafe walking surface.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11167

1910.106 B07 I

Serious Gravity 10 1 instance 20 exposed
Issued
May 12, 2022
Abate by
Jun 8, 2022
Penalty
Initial $11,167 · Current $7,817 Reduced
29 CFR 1910.106(b)(7)(i): The American Society of Mechanical Engineers (ASME) code stamp, American Petroleum Institute (API) monogram or the label of the Underwriters' Laboratories, Inc. on a tank was not present as evidence for strength test compliance:  a) 700 New Castle Ave Wilmington, DE 19801: On or about November 16, 2022, the employers were supplying and operating a 250-gallon portable diesel tank that was manufactured and did not have the required label identifying evidence for strength test compliance.
Recent events (2)
  • — I (S) $7816.9
  • — Z (S) $11167

1910.106 D02 II

Serious Gravity 5 1 instance 20 exposed
Issued
May 12, 2022
Abate by
Jun 8, 2022
Penalty
Initial $7,977 · Current $5,584 Reduced
29 CFR  1910.106(d)(2)(ii): "Emergency venting." Each portable tank shall be provided with one or more devices installed in the top with sufficient emergency venting capacity to limit internal pressure under fire exposure conditions to 10 psig, or 30 percent of the bursting pressure of the tank, whichever is greater. The total venting capacity shall be not less than that specified in paragraphs (b)(2)(v) (c) or (e) of this section. At least one pressure-activated vent having a minimum capacity of 6,000 cubic feet of free air (14.7 psia and 60 deg. F.) shall be used. It shall be set to open at not less than 5 psig. If fusible vents are used, they shall be actuated by elements that operate at a temperature not exceeding 300 deg. F:  (a) 700 New Castle Ave Wilmington, De. 19801: On or about November 16, 2022, the employer failed to provide each portable tank with one or more devices installed in the top with sufficient emergency venting capacity to limit internal pressure under fire exposure conditions to 10 psig, or 30 percent of the bursting pressure of the tank, whichever is greater as required.
Recent events (2)
  • — I (S) $5583.9
  • — Z (S) $7977

1910.157 C04

Other-than-serious Gravity 10 1 instance 20 exposed
Issued
May 12, 2022
Penalty
Initial $11,167 · Current $7,817 Reduced
29 CFR  1910.157(c)(4):Portable fire extinguishers were not maintained in a fully charged and operable condition:  a) 700 New Castle Ave Wilmington, DE 19801 (At portable fuel tank): On or about November 16, 2022, the employer did not provide a working/usable fire extinguisher at the site where employees were required to use flammable fuels to perform their required daily duties. Upon inspection the fire extinguisher was depleted and provided no fire fighting capability.
Recent events (2)
  • — I (O) $7816.9
  • — Z (S) $11167

1910.1200 F06 II

Other-than-serious Gravity 5 1 instance 20 exposed
Issued
May 12, 2022
Abate by
Jun 8, 2022
Penalty
Initial $9,572 · Current $6,700 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemicals:   a) 700 New Castle Ave Wilmington, DE 19801: On or about November 16, 2022, the employers were supplying and operating a 250-gallon portable diesel tank that was manufactured and did not have the required HazCom labeling identifying potential hazards.
Recent events (2)
  • — I (O) $6700.4
  • — Z (S) $9572

1910.134 C02 I

Other-than-serious 1 instance 20 exposed
Issued
May 12, 2022
Abate by
Jun 8, 2022
Penalty
Initial $896 · Current $0 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) 700 New Castle Ave Wilmington, De. 19801: On or about November 16, 2022, the employer failed to ensure that voluntary respirator users were provided with the information contained in Appendix D of 29 CFR 1910.134.
Recent events (2)
  • — I (O) $0
  • — Z (O) $896

View Intercontinental Services of Delaware, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345638860.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.