Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JONES LANG LASALLE AMERICAS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JONES LANG LASALLE AMERICAS, INC. in 2841 ACCESS ROAD, DAVENPORT, FL 33897 (NAICS 531312). OSHA activity number 345667026.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jones Lang Lasalle Americas, INC. — free Get an email when a new federal OSHA severe-injury report for Jones Lang Lasalle Americas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2841 ACCESS ROAD
City
DAVENPORT
State
FL
ZIP
33897
Mailing
4373 SEVEN CANYONS DR., KISSIMMEE, FL 34746
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531312
Employees
251
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 24, 2022
Abate by
Mar 22, 2022
Penalty
Initial $13,674 · Current $8,204 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a. On or about November 24, 2021, an employee was working from atop an A-Frame ladder, while performing repairs on a water heater, during which time the employee did not utilize, nor had the employer developed, documented and utilized procedures for the control of hazardous energy; therefore exposing the employee to electrical, thermal burn and fall hazards.
Recent events (2)
  • — I (S) $8204.4
  • — Z (S) $13674

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 24, 2022
Abate by
Mar 22, 2022
Penalty
Initial $13,674 · Current $8,204 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and Control:  a. On or about November 24, 2021, an employee was working from atop an A-Frame ladder, while performing repairs on a water heater, during which the employer did not provide the authorized employee, instruction/ training in the recognition of applicable hazardous energy sources, nor training on the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control; therefore exposing the employee to electrical, thermal burn and fall hazards.
Recent events (2)
  • — I (S) $8204.4
  • — Z (S) $13674

View Jones Lang Lasalle Americas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345667026.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.