Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAST COAST CABINETRY, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of EAST COAST CABINETRY, INC. in 93-08 95TH AVENUE, OZONE PARK, NY 11416 (NAICS 337110). OSHA activity number 345667703.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch East Coast Cabinetry, INC. — free Get an email when a new federal OSHA severe-injury report for East Coast Cabinetry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
93-08 95TH AVENUE
City
OZONE PARK
State
NY
ZIP
11416
Mailing
9308 95TH AVENUE, OZONE PARK, NY 11416
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
8
Ownership type
A

8 citations on file for this inspection.

1910.107 G02

Serious Gravity 10 1 instance 8 exposed
Issued
May 27, 2022
Penalty
Initial $5,801 · Current $3,480 Reduced
29 CFR  1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:   (a) Worksite- On or about December 3, 2021, the employer did not keep the cleanliness of the spraying area, deposits of combustible residues were observed accumulated on building structures and equipment with a 120V AC electrical receptacle.
Recent events (2)
  • — I (S) $3480
  • — Z (S) $5801

1910.107 C06

Serious Gravity 10 1 instance 2 exposed
Issued
May 27, 2022
Abate by
Jun 24, 2022
Penalty
Initial $5,801 · Current $3,480 Reduced
29 CFR  1910.107(c)(6):Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  (a) Worksite- On or about December 3, 2021, in the spraying area a 120V electrical receptacle was observed covered with combustible residues and was not explosion-proof type classified for the hazardous location.
Recent events (2)
  • — I (S) $3480
  • — Z (S) $5801

1910.134 C01

Serious Gravity 10 1 instance 8 exposed
Issued
May 27, 2022
Abate by
Jun 24, 2022
Penalty
Initial $5,801 · Current $3,480 Reduced
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   (a) Worksite- On or about December 3, 2021, the employer had not developed and implemented a written respiratory protection program with worksite specific procedures for employees that were required to use respirators, such as but not limited to, elastomeric half face masks and N95 respirators when manufacturing custom wooden cabinets and countertops.
Recent events (2)
  • — I (S) $3480
  • — Z (S) $5801

1910.134 E01

Serious Gravity 10 1 instance 8 exposed
Issued
May 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   (a) Worksite- On or about December 3, 2021, the employer did not provide medical evaluation for employees that were required to use respirators, such as but not limited to, elastomeric half face masks and N95 respirators when manufacturing custom wooden cabinets and countertops.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 10 1 instance 8 exposed
Issued
May 27, 2022
Abate by
Jun 24, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   (a) Worksite- On or about December 3, 2021, the employer did not complete respirator fit testing for employees that were required to use respirators, such as but not limited to, elastomeric half face masks and N95 respirators when manufacturing custom wooden cabinets and countertops.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 10 1 instance 8 exposed
Issued
May 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:   (a) Worksite- On or about December 3, 2021, the employer did not provide respiratory protection training prior to requiring employees to use respirators, such as but not limited to, elastomeric half face masks and N95 respirators when manufacturing custom wooden cabinets and countertops.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01 I

Serious Gravity 5 1 instance 8 exposed
Issued
May 27, 2022
Abate by
Jun 24, 2022
Penalty
Initial $4,972 · Current $2,985 Reduced
29 CFR  1910.1200(e)(1)(i):The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  (a) Worksite- On or about December 3, 2021, the employer had not completed a list of the hazardous chemicals known to be present  at worksite to  employees who were exposed to hazardous chemicals, including, but not limited to, flammable aerosol paints, adhesives, industrial cleaners, and paint thinners.
Recent events (2)
  • — I (S) $2985
  • — Z (S) $4972

1910.1200 H01

Serious Gravity 5 1 instance 8 exposed
Issued
May 27, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Worksite- On or about December 3, 2021, the employer did not provide training and information on hazard communication to employees who were working with and around hazardous chemicals including, but not limited to, flammable aerosol paints, adhesives, industrial cleaners, and paint thinners.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View East Coast Cabinetry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345667703.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.