BERGEN, NY —
OSHA Inspection: BONDUELLE USA, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BONDUELLE USA, INC. in 15 CHURCH STREET, BERGEN, NY 14416 (NAICS 311411). OSHA activity number 345672992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BONDUELLE USA, INC.
- Site address
- 15 CHURCH STREET
- City
- BERGEN
- State
- NY
- ZIP
- 14416
- Mailing
- 15 CHURCH STREET, BERGEN, NY 14416
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311411
- Employees
- 160
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.119 D03 I B
- Issued
- Jun 1, 2022
- Abate by
- Jul 5, 2022
- Penalty
- Initial $10,360 · Current $6,667 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): The employer did not include all equipment that was part of the process on piping and instrument diagrams. (a) Anhydrous ammonia refrigeration system 2 - On or about 1/10/22, Refrigeration mechanics/maintenance were exposed to a release of ammonia gas and liquid during maintenance activities such as oil draining. CD-2-4 BAC VXC-N-325 condenser and CD-2-3 BAC VAC-350 condenser were removed and replaced by an Evapco PMC-939E condenser (project completed on 5/19/21.) CD-2-4 BAC VXC-N-325 condenser and CD-2-3 BAC VAC-350 condenser remain listed on the piping and instrument diagram, Engine Room #2 Condenser & H.P.R's, rev. 6/22/20. Evapco PMC-939E condenser was not listed on the piping and instrument diagrams. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $6667
- — Z (S) $10360
1910.119 D03 II
- Issued
- Jun 1, 2022
- Abate by
- Jul 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.(a) (LOCATION) (IDENTIFY SPECIFIC PROCESS OPERATIONS AND/OR CONDITIONS) a) Anhydrous Ammonia System 1 Engine Room: On or about 12/21/2021, the employer did not document that the engine room emergency ventilation system complied with RAGAGEP, such as but not limited to, ANSI/IIAR 6 - 2019 Standard for Inspection, Testing, and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Chapter 12, Table 12.1 Emergency Ventilation Systems Inspection, Testing, and Maintenance Tasks, when inspections and tests were not performed on the emergency ventilation system equipment. Failure of the emergency ventilation system would result in an accumulation of hazardous levels of anhydrous ammonia in the engine room during an uncontrolled release, exposing employees to fire, explosion, and toxic hazards. b) Anhydrous Ammonia System 2 Engine Room: On or about 12/21/2021, the employer did not document that the engine room emergency ventilation system complied with RAGAGEP, such as but not limited to, ANSI/IIAR 6 - 2019 Standard for Inspection, Testing, and Maintenance of Closed-Circuit Ammonia Refrigeration Systems, Chapter 12, Table 12.1 Emergency Ventilation Systems Inspection, Testing, and Maintenance Tasks, when inspections and tests were not performed on the emergency ventilation system equipment. Failure of the emergency ventilation system would result in an accumulation of hazardous levels of anhydrous ammonia in the engine room during an uncontrolled release, exposing employees to fire, explosion, and toxic hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 F01 III B
- Issued
- Jun 1, 2022
- Abate by
- Jul 5, 2022
- Penalty
- Initial $10,360 · Current $6,667 Reduced
General-duty citation text
29 CFR 1910.119(f)(1)(iii)(B): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information that addressed health and safety considerations, such as precautions necessary to prevent exposure, including engineering controls, administrative controls, and personal protective equipment. a) On or about 1/11/22, Bonduelle USA Inc. - Bergen Facility, Standard Operating Procedure - Section 4, Mycom -225-ME DUAL compresssor, C11, engine room system #1, did not include clear instructions for safely conducting activities involved in each covered process consistent with the process safety information addressing safety and health considerations: Precautions necessary to prevent exposure, including engineering controls and administrative controls. b) On or about 1/11/22, Bonduelle USA Inc. - Bergen Facility, Standard Operating Procedure - Section 4, Sullair C compressor, Engine room system #2, CBC-2, did not include clear instructions for safely conducting activities involved in each covered process consistent with the process safety information addressing safety and health considerations: Precautions necessary to prevent exposure, including engineering controls and administrative controls. c) On or about 1/11/22, Bonduelle USA Inc. - Bergen Facility, Standard Operating Procedure - Section 4, GM 110 compressor, Engine room system #2, CC 3, did not include clear instructions for safely conducting activities involved in each covered process consistent with the process safety information addressing safety and health considerations: Precautions necessary to prevent exposure, including engineering controls and administrative controls. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $6667
- — Z (S) $10360
1910.119 J04 IV
- Issued
- Jun 1, 2022
- Abate by
- Jul 5, 2022
- Penalty
- Initial $10,360 · Current $6,666 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The documentation of each inspection and test that was performed on the process did not identify the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test: a) On or about 1/10/21, anhydrous ammonia refrigeration system #1 contains 40,393 pounds of anhydrous ammonia. Refrigeration mechanics/maintenance were exposed to the release of ammonia gas and liquid when conducting daily checks and during oil draining. The employer did not document that system piping has been inspected. b) On or about 1/10/21, anhydrous ammonia refrigeration system #2 contains 47,502 pounds of anhydrous ammonia. Refrigeration mechanics/maintenance were exposed to the release of ammonia gas and liquid when conducting daily checks and during oil draining. The employer did not document that system piping has been inspected. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $6666
- — Z (S) $10360
More inspections at Bonduelle USA, INC.
View Bonduelle USA, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311411)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345672992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.