OSHA Inspection: INTERSTEEL GROUP, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INTERSTEEL GROUP, LLC. in BLDG 233 BLUEGRASS ARMY DEPOT, RICHMOND, KY 40475 (NAICS 236210). OSHA activity number 345673107.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intersteel Group, LLC. — free Get an email when a new federal OSHA severe-injury report for Intersteel Group, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 233 BLUEGRASS ARMY DEPOT
City
RICHMOND
State
KY
ZIP
40475
Mailing
819 PORTER PLACE, LEXINGTON, KY 40508
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
26
Ownership type
A

6 citations on file for this inspection.

1926.250 B08 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $9,753 · Current $5,852 Reduced
29 CFR  1926.250(b)(8)(i): Used lumber did not have all nails withdrawn before stacking:  a) Bluegrass Army Depot - Bldg. 233: On or about 12/07/2021 and days prior, the employer exposed employees to an impalement hazard, the nails from stacked wood were not removed or made safe.   b) Bluegrass Army Depot - Bldg. 233: On or about 12/07/2021 and days prior, the employer exposed employees to an impalement hazard, the nails from lumber laying on the floor/ground were not removed or made safe.
Recent events (2)
  • — I (S) $5851.8
  • — Z (S) $9753

1926.405 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1926.405(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor and so connected to all boxes, fittings, and cabinets;   a) Bluegrass Army Depot - Bldg. 233: On or about 12/07/2021, the employer exposed workers to electrical hazards in that the energized electrical metal enclosure and conduit was not metallically joined together resulting an opening to the enclosure and abrasion to the energized conductors.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1926.405 J01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1926.405(j)(1)(i): Live parts. Fixtures, lamp holders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lamp holders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.   a) Bluegrass Army Depot - Bldg. 233: On or about 12/07/2021 and days prior, the employer exposed employees to electrical hazards in that conductors for an electrical outlet were energized.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1904.40 A

Other-than-serious 1 instance 4 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $1,366 · Current $820 Reduced
29 CFR  1904.40(a):The employer did not provide an authorized government representative the records within the four business hours.  a) Bluegrass Army Depot - Bldg. 233: On or about 12/07/2021 and days prior, the employer did not provide the OSHA 300 logs following multiple requests.
Recent events (2)
  • — I (O) $819.6
  • — Z (O) $1366

1926.150 C01 VIII

Other-than-serious 1 instance 1 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970:  a) Bluegrass Army Depot - Bldg 233: On or about 12/07/2021 and days prior, the employer exposed employees to a fire hazard, the scissor lift portable fire extinguisher did not have the maintenance log attached or on file for review IAW NFPA 10A-1970.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.451 G04 IV

Other-than-serious 1 instance 1 exposed
Issued
Jan 7, 2022
Abate by
Jan 20, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface:  a) Bluegrass Army Depot - Bld 233: On or about 12/07/2021 and days prior, the employer exposed employees to a fall hazard in that the scissor lift mid-rail was not installed halfway between the guardrail and platform.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Intersteel Group, LLC.'s full OSHA safety record →