Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APC SPECIALIST LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of APC SPECIALIST LLC in 35 FRANKFORT ST. ARCH BLOCK E. SPAN 15, NEW YORK, NY 10038 (NAICS 237310). OSHA activity number 345674220.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch APC Specialist LLC — free Get an email when a new federal OSHA severe-injury report for APC Specialist LLC is published. One employer, no account, unsubscribe in one click.
Establishment
APC SPECIALIST LLC
Site address
35 FRANKFORT ST. ARCH BLOCK E. SPAN 15
City
NEW YORK
State
NY
ZIP
10038
Mailing
132-02 89TH AVENUE, RICHMOND HILL, NY 11418
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
237310
Employees
17
Ownership type
A

3 citations on file for this inspection.

1926.302 B10

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 1, 2022
Abate by
Jun 13, 2022
Penalty
Initial $10,151 · Current $10,100 Reduced
29 CFR  1926.302(b)(10): Abrasive blast cleaning nozzles were not equipped with an operating valve which must be held open manually:  Location: 35 Frankfort St., New York, NY 10038 at Arch Block E Span 15   On or about: 12/2/2021   a) Employees bypassed the manual operational switch of an abrasive blast cleaning nozzle.
Recent events (3)
  • — F (S) $10100
  • — C (S) $10151
  • — Z (S) $10151

1926.451 C01 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 1, 2022
Abate by
Jun 13, 2022
Penalty
Initial $10,151 · Current $10,100 Reduced
29 CFR  1926.451(c)(1)(iii): Ties, guys, braces, or outriggers were not installed to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, was applied or was transmitted to the scaffold:   Location: 35 Frankfort St., New York, NY 10038 at Arch Block E Span 15   On or about: 12/2/2021  a) Employees worked while standing on outriggers installed on a two-tier high tubular welded frame mobile scaffold that was not tied, braced, or supported to prevent tipping.
Recent events (3)
  • — F (S) $10100
  • — C (S) $10151
  • — Z (S) $10151

1926.451 G01 VII

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 1, 2022
Abate by
Jun 13, 2022
Penalty
Initial $10,151 · Current $0 Reduced
29 CFR  1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  Location: 35 Frankfort St., New York, NY 10038 at Arch Block E Span 15   On or about: 12/2/2021   a) Employees worked from a two-tier tubular welded frame mobile scaffold and did not utilize any fall protection system when abrasive blasting the steel beams.
Recent events (3)
  • — F (S) $0
  • — C (S) $10151
  • — Z (S) $10151

View APC Specialist LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345674220.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.