Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAR TECHNOLOGIES, L.L.C.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BAR TECHNOLOGIES, L.L.C. in 500 FLUID POWER DRIVE, GENEVA, IL 60134 (NAICS 331221). OSHA activity number 345679781.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BAR Technologies, L.L.C. — free Get an email when a new federal OSHA severe-injury report for BAR Technologies, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
500 FLUID POWER DRIVE
City
GENEVA
State
IL
ZIP
60134
Mailing
500 FLUID POWER DRIVE, GENEVA, IL 60134
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
26
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 12, 2022
Abate by
Jun 10, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.147(c)(7)(i):The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  On or about December 9, 2021, the employer did not ensure that employees were trained to isolate hazardous energy sources prior to engaging in servicing and maintenance activities.  Employees performed setup and tool changes on the Hetran turning machine without first shutting down and locking out the hydraulic and electrical energy sources, exposing them to crushing injuries.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
May 12, 2022
Abate by
Jul 15, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.147(d): The application of energy control (lockout or tagout) actions were not done in the following sequence:  On or about December 9, 2021 employee(s) performed servicing and maintenance tasks such as setup on the Hetran Machine, and were exposed to bodily injury and crushing hazards due to unexpected startup and/or energy release of stored energy.  Employees were not required to control hazardous energy sources in the following sequence:    (1) prepare for shutdown, (2) shut down machine or equipment, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device by authorized employee, (5) relieve, disconnect, restrain or otherwise render safe all stored or residual energy, (6) verify that isolation and deenergization of the machine or equipment have been accomplished:  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

View BAR Technologies, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345679781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.