Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M. ARG?ESO & CO DBA PARAMELT-USA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of M. ARG?ESO & CO DBA PARAMELT-USA in 12651 ELMWOOD AVE, CLEVELAND, OH 44111 (NAICS 325520). OSHA activity number 345686877.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M. Arg?Eso & CO DBA Paramelt-Usa — free Get an email when a new federal OSHA severe-injury report for M. Arg?Eso & CO DBA Paramelt-Usa is published. One employer, no account, unsubscribe in one click.
Site address
12651 ELMWOOD AVE
City
CLEVELAND
State
OH
ZIP
44111
Mailing
2817 MCCRACKEN, MUSKEGON, MI 49441
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325520
Employees
31
Ownership type
A

7 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 18, 2022
Penalty
Initial $13,052 · Current $6,526 Reduced
29 CFR  1910.132(a):Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  On or about December 5, 2021, where employees are exposed to thermal burns from hazards such as hot wax and steam while performing tasks including but not limited to steaming and disconnecting hoses in the tank 42 area, the employer did not ensure that employees wore protective equipment including, but not limited to heat protective gloves and sleeves.
Recent events (2)
  • — I (S) $6526
  • — Z (S) $13052

1910.132 D01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 24, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(1):The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  On or about December 14, 2021, the employer had not conducted and certified a hazard assessment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 F01 II

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.132(f)(1)(ii):The employer did not provide training to each employee who is required by this section to use PPE on knowing what PPE is necessary:  On or about December 5, 2021, the employer did not ensure that employees performing tasks including but not limited to steaming and disconnecting hoses in the tank 42 area received training on what PPE is necessary while performing the task.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:  On or about December 5, 2021, where employees are exposed to thermal burns from hazards such as hot wax and steam while performing tasks including but not limited to steaming and disconnecting hoses in the tank 42 area, the employer did not ensure that employees wore protective equipment including, but not limited to splash resistant goggles and face shields.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Penalty
Initial $13,052 · Current $9,136 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about December 5, 2021, the employer had not ensured that procedures were documented and utilized for the control of potentially hazardous energy including but not limited to electrical as well as steam/wax pressure and heat, while removing hoses in the tank 42 area.
Recent events (2)
  • — I (S) $9136.4
  • — Z (S) $13052

1910.147 C07 I A

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On or about December 5, 2021, the employer had not ensured that those employees tasked with shutting down tank 42 equipment, steaming, and removing flexible hoses received training on applicable hazardous energy sources in the area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 28, 2022
Abate by
Mar 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about December 5, 2021, employees were exposed to electrical, thermal, and steam pressure hazards associated with shutdown of equipment, steaming and removal of flexible hoses in the tank 42 area. The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect or steam and wax lines [per 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.   prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy;  shutdown the machine or equipment [(d)(2)];  machine isolation [(d)(3)] - Physically locate and operate all energy isolating devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s);  LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device;  dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy;  verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View M. Arg?Eso & CO DBA Paramelt-Usa's full OSHA safety record →