PANAMA CITY BEACH, FL —
OSHA Inspection: EVANS HOME CENTER OF BAY COUNTY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EVANS HOME CENTER OF BAY COUNTY in 17760 PANAMA CITY BEACH PARKWAY, PANAMA CITY BEACH, FL 32413 (NAICS 453998). OSHA activity number 345688725.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EVANS HOME CENTER OF BAY COUNTY
- Site address
- 17760 PANAMA CITY BEACH PARKWAY
- City
- PANAMA CITY BEACH
- State
- FL
- ZIP
- 32413
- Mailing
- 17760 PANAMA CITY BEACH PARKWAY, PANAMA CITY BEACH, FL 32413
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453998
- Employees
- 41
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 1, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $4,931 · Current $4,931
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm including injuries from crushing or tip over of racks and stored items to employees in that employees were exposed to crush by or falling object hazards from storage racks not being secured to the concrete floor. a) Warehouse Area: On or about December 15, 2021 and at times prior to, the employer exposed employees to struck-by, and crushing hazards in that the employer permitted employees operating powered industrial trucks to load multiple boxes weighing 200 pounds each on to storage racks that were not bolted to the concrete floor.
Recent events (1)
- — Z (S) $4931
1910.305 B01 II
- Issued
- Mar 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Warehouse area: On or about December 15, 2021 and at times prior to, the employer failed to ensure that the 110 volt junction box did not have a cover on it.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Mar 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Garden/Outdoor Area : On or about December 15, 2021 and at times prior to, the employer allowed temporary wiring to be used as permanent wiring to provide power to the cash register/computer area from 110 volt power strip.
Recent events (1)