WASHINGTON, DC —
OSHA Inspection: NICOL CONSTRUCTION, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NICOL CONSTRUCTION, LLC. in 1026 18TH STREET, NE, WASHINGTON, DC 20002 (NAICS 236118). OSHA activity number 345691547.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NICOL CONSTRUCTION, LLC.
- Site address
- 1026 18TH STREET, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 1112 STAPLE STREET, NE UNIT #1, WASHINGTON, DC 20002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 D01
- Issued
- May 25, 2022
- Abate by
- Jun 1, 2022
- Penalty
- Initial $1,678 · Current $900 Reduced
General-duty citation text
29 CFR 1926.403(d)(1):Electric equipment was not firmly secured to the surface on which it was mounted: a) Lower Level - Employees were using (2) three way temporary outlets to supply power to extension cords and the outlets were laying on the floor, 120 volt, 15 amp service, on or about 12/16/2021. b) Lower Level - Employees were using a temporary service panel that was not secured and was suspended by the conductors, 120 volt, 100 amp service, on or about 12/16/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $900
- — Z (S) $1678
1926.405 B01
- Issued
- May 25, 2022
- Abate by
- Jun 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(1):Unused openings in cabinets, boxes, and fittings were not effectively closed: a) Lower Level - Employees were using a temporary service panel and 6 of the circuit openings were not provided with covers exposing live electrical parts, 120 volt, 100 amp service, on or about 12/16/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- May 25, 2022
- Abate by
- Jun 1, 2022
- Penalty
- Initial $3,916 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Roof - Employees were removing sub roofing from a flat roof and not protected from a 22 foot and an 11 foot fall hazard, on or about 12/16/2021. b) Rear of Row House - Employees were walking across a lower level patio well on an 11 inch board and exposed to a 9 foot fall hazard, on or about 12/16/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2000
- — Z (S) $3916
More inspections at Nicol Construction, LLC.
View Nicol Construction, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345691547.