OSHA Inspection: WSP USA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WSP USA, INC. in CALLE ATOCHA #92 OLD USPS ATOCHA STATION, PONCE, PR 00731 (NAICS 236220). OSHA activity number 345692891.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WSP USA, INC. — free Get an email when a new federal OSHA severe-injury report for WSP USA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WSP USA, INC.
Site address
CALLE ATOCHA #92 OLD USPS ATOCHA STATION
City
PONCE
State
PR
ZIP
00731
Mailing
350 EAGLEVIEW BOULEVARD, EXTON, PA 19341
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

2 citations on file for this inspection.

1910.147 A03 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2022
Penalty
Initial $12,431 · Current $0 Reduced
29 CFR  1910.147(a)(3)(i): The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.    On or about 1 Dec 2021, at U.S. Postal Service Ponce Atocha location, Ponce, Puerto Rico.  An employee engaged in a debris clean-up operation was exposed to 2nd degree electrical burns while removing high vegetation of the surroundings of an electrical power sub-station not secured or blocked.  WSP USA failed to identify the energy source and failed to lockout all disconnect sources.  NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12431

1910.147 F02 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 21, 2022
Penalty
Initial $12,431 · Current $0 Reduced
29 CFR  1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures:   On or about 1 Dec 2021, at U.S. Postal Service Ponce Atocha location, Ponce, Puerto Rico.  An employee engaged in a debris clean-up operation was exposed to 2nd degree electrical burns while removing high vegetation of the surroundings of an electrical power sub-station that was not secured or blocked from releasing energy sources.  WSP USA  failed to inform the Sunset Contractors that the electrical power station was not blocked nor de-energized.    NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12431

View WSP USA, INC.'s full OSHA safety record →