MITCHELL, SD —
OSHA Inspection: IVERSON CHRYSLER CENTER, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IVERSON CHRYSLER CENTER, INC. in 600 SOUTH BURR STREET, MITCHELL, SD 57301 (NAICS 811198). OSHA activity number 345698914.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IVERSON CHRYSLER CENTER, INC.
- Site address
- 600 SOUTH BURR STREET
- City
- MITCHELL
- State
- SD
- ZIP
- 57301
- Mailing
- 600 SOUTH BURR STREET, MITCHELL, SD 57301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811198
- Employees
- 35
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B01
- Issued
- Apr 1, 2022
- Abate by
- Apr 27, 2022
- Penalty
- Initial $4,351 · Current $2,611 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) Iverson Chrysler Center, Inc. at 600 South Burr Street, Mitchell, SD 57301: On or about and at times prior to December 21, 2021, the employer did not ensure that the electrical connector on the main lift motor on Bay #13 was free of hazards in that the main electrical connector was damaged which exposed employees to the inner conductors. This condition exposed employees to electrical shock and fire hazards.
Recent events (2)
- — I (S) $2610.6
- — Z (S) $4351
1910.334 A02 II
- Issued
- Apr 1, 2022
- Abate by
- Apr 27, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: (a) Iverson Chrysler Center, Inc. at 600 South Burr Street, Mitchell, SD 57301: On or about and at times prior to December 21, 2021, the employer did not ensure that a retractable extension cord used within the area of Bay # 1 was removed from service due to the outer sheathing being damaged which exposed the inner conductors. This condition exposed employees to electrical shock and fire hazards.