MESQUITE, TX —
OSHA Inspection: SENOX CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SENOX CORPORATION in 227 S TOWN EAST BLVD., MESQUITE, TX 75149 (NAICS 339999). OSHA activity number 345699490.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SENOX CORPORATION
- Site address
- 227 S TOWN EAST BLVD.
- City
- MESQUITE
- State
- TX
- ZIP
- 75149
- Mailing
- 227 S TOWN EAST BLVD., MESQUITE, TX 75149
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 75
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Apr 20, 2022
- Abate by
- Jun 16, 2022
- Penalty
- Initial $10,151 · Current $6,091 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) On or about August 4, 2021, and times prior to employees were exposed to a caught-in hazard by not having energy control program and training for employees. b) On or about August 4, 2021, and times prior to employees were exposed to a caught-in hazard when setting up slitter 2 without an energy control program. c) On or about August 4, 2021, and times prior to employees were exposed to a caught-in hazard when cleaning slitter 2 without an energy control program.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
1910.212 A03 II
- Issued
- Apr 20, 2022
- Penalty
- Initial $10,151 · Current $6,091 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. On or about August 4, 2021, and times prior to employees were exposed to a caught-in hazard when cleaning the rolls without a guard.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
1910.219 C02 I
- Issued
- Apr 20, 2022
- Abate by
- Jun 16, 2022
- Penalty
- Initial $10,151 · Current $6,091 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. On or about August 04, 2021, and times prior employees were exposed to a caught in hazard by not having a horizontal shaft guarded on slitter 2 in the cut department.
Recent events (2)
- — I (S) $6090.6
- — Z (S) $10151
More inspections at Senox Corporation
View Senox Corporation's full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345699490.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.