OSHA Inspection: DEL VALLE GROUP, SP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DEL VALLE GROUP, SP in PRPA D&B EMERGENCY REPAIR PIER 3, SAN JUAN, PR 00936 (NAICS 237310). OSHA activity number 345701577.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DEL Valle Group, SP — free Get an email when a new federal OSHA severe-injury report for DEL Valle Group, SP is published. One employer, no account, unsubscribe in one click.
Establishment
DEL VALLE GROUP, SP
Site address
PRPA D&B EMERGENCY REPAIR PIER 3
City
SAN JUAN
State
PR
ZIP
00936
Mailing
CARR 865 KM 0.6 BO CAMPANILLAS, TOA BAJA, PR 00951
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
15
Ownership type
A

4 citations on file for this inspection.

1926.150 C01 VI

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 28, 2022
Penalty
Initial $4,438 · Current $2,662 Reduced
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:  On or about 16 Dec 2021, at next to diesel tank and at inside of storage trailer next to two oxygen and acetylene cylinders, on top of marine barge, Pier 3, San Juan, Puerto Rico.  Employees were exposed to fire hazards while performing emergency repairs on a pier within the premises of a hoisting crane, diesel tank, oxygen and acetylene cylinders and combustible materials next to it with no fire extinguishers available or provided in case of a sudden fire.     NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $2662
  • — Z (S) $4438

1926.350 A09

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 28, 2022
Penalty
Initial $4,931 · Current $2,958 Reduced
29 CFR  1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times:   On or about 16 Dec 2021, inside of storage trailer, on top of marine barge, Pier 3, San Juan, Puerto Rico.  In areas where flammables and combustibles materials and compressed gas cylinders were located, compressed gas cylinders (oxygene and acetylene) were left consecutive days stored together un-secured.  NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $2958
  • — Z (S) $4931

1926.1416 D03 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 28, 2022
Abate by
Feb 8, 2022
Penalty
Initial $6,164 · Current $3,698 Reduced
29 CFR  1926.1416(d)(3)(i): The crane was not equipped with a functioning anti-two block device:   On or about 16 Dec 2021, at top of marine construction barge, at Repairs Pier #3, San Juan Bay, PR.  Employees engaged on marine construction operations were exposed to struck-by hazards in the event of a sudden free fall of large heavy underwater cutting steel tool hoisted by a crane which lacked an anti-two blocking device.    NOTE:	Certification of abatement must be submitted for this citation item as required by 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $3698
  • — Z (S) $6164

1926.1424 A02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 28, 2022
Penalty
Initial $6,164 · Current $3,698 Reduced
29 CFR  1926.1424(a)(2)(ii): To prevent employees from entering hazard areas, the employer did not erect and maintain control lines, warning lines, railings or similar barriers to mark the boundaries of the hazard areas and/or did not train each employee to understand what these markings signify:   On or about 16 Dec 2021, at top of marine construction barge, at Repairs Pier #3, San Juan Bay, PR.  Employees engaged on marine construction operations were exposed to struck-by hazards while a hoisting crane was operated without warning lines or barriers to delineate its 360 degrees radius.  NOTE: Certification of abatement is not required for this citation item as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $3698
  • — Z (S) $6164

View DEL Valle Group, SP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345701577.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.