Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAR PLATING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BAR PLATING, LLC in 30-7 POWERS DRIVE, MERIDEN, CT 06451 (NAICS 332813). OSHA activity number 345702906.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BAR Plating, LLC — free Get an email when a new federal OSHA severe-injury report for BAR Plating, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BAR PLATING, LLC
Site address
30-7 POWERS DRIVE
City
MERIDEN
State
CT
ZIP
06451
Mailing
30-7 POWERS DRIVE, MERIDEN, CT 06451
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.219 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 10, 2022
Abate by
Jul 29, 2022
Penalty
Initial $4,351 · Current $2,176 Reduced
29 CFR  1910.219(a)(2):29 CFR 1910.219(a)(2): Vertical and inclined belts (paragraphs (e) (3) and (4) of this section) if not more than two and one-half (2 1/2) inches wide and running at a speed of less than one thousand (1,000) feet per minute, and if free from metal lacings or fastenings were not guarded with a nip-point belt and pulley guard.  Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the rotating inclined vertical "V" belt of the "Excelsior 1088" buffing machine was unguarded.
Recent events (2)
  • — I (S) $2175.5
  • — Z (S) $4351

1910.219 C02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 10, 2022
Abate by
Jul 29, 2022
Penalty
Initial $4,351 · Current $2,176 Reduced
29 CFR  1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the horizontal shaft of the "Excelsior 1088" buffing machine that contained a wire brush was unguarded.
Recent events (2)
  • — I (S) $2175.5
  • — Z (S) $4351

1910.219 C04 I

Serious Gravity 10 2 instances 3 exposed
Issued
Jun 10, 2022
Abate by
Jul 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.219(c)(4)(i):Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the horizontal shaft end point and the rear pulley end nut of "Excelsior 1088"  buffing machine were unguarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 10 3 instances 3 exposed
Issued
Jun 10, 2022
Abate by
Jul 29, 2022
Penalty
Initial $4,351 · Current $2,176 Reduced
29 CFR  1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the two front and one rear rotating pulleys of  "Excelsior 1088" buffing machine were unguarded.
Recent events (2)
  • — I (S) $2175.5
  • — Z (S) $4351

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 10, 2022
Abate by
Jul 29, 2022
Penalty
Initial $2,486 · Current $1,243 Reduced
29 CFR  1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:(a) (LOCATION) (IDENTIFY EQUIPMENT AND CONDITION(S)) (STATE HAZARD(S) TO EMPLOYEE(S))  Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the electrical outlet on the wall adjacent to the buffing machines was not equipped with a cover as the faceplate was broken.
Recent events (2)
  • — I (S) $1243
  • — Z (S) $2486

View BAR Plating, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345702906.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.