MERIDEN, CT —
OSHA Inspection: BAR PLATING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BAR PLATING, LLC in 30-7 POWERS DRIVE, MERIDEN, CT 06451 (NAICS 332813). OSHA activity number 345702906.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAR PLATING, LLC
- Site address
- 30-7 POWERS DRIVE
- City
- MERIDEN
- State
- CT
- ZIP
- 06451
- Mailing
- 30-7 POWERS DRIVE, MERIDEN, CT 06451
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.219 A02
- Issued
- Jun 10, 2022
- Abate by
- Jul 29, 2022
- Penalty
- Initial $4,351 · Current $2,176 Reduced
General-duty citation text
29 CFR 1910.219(a)(2):29 CFR 1910.219(a)(2): Vertical and inclined belts (paragraphs (e) (3) and (4) of this section) if not more than two and one-half (2 1/2) inches wide and running at a speed of less than one thousand (1,000) feet per minute, and if free from metal lacings or fastenings were not guarded with a nip-point belt and pulley guard. Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the rotating inclined vertical "V" belt of the "Excelsior 1088" buffing machine was unguarded.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
1910.219 C02 I
- Issued
- Jun 10, 2022
- Abate by
- Jul 29, 2022
- Penalty
- Initial $4,351 · Current $2,176 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the horizontal shaft of the "Excelsior 1088" buffing machine that contained a wire brush was unguarded.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
1910.219 C04 I
- Issued
- Jun 10, 2022
- Abate by
- Jul 29, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i):Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the horizontal shaft end point and the rear pulley end nut of "Excelsior 1088" buffing machine were unguarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Jun 10, 2022
- Abate by
- Jul 29, 2022
- Penalty
- Initial $4,351 · Current $2,176 Reduced
General-duty citation text
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the two front and one rear rotating pulleys of "Excelsior 1088" buffing machine were unguarded.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
1910.305 B02 I
- Issued
- Jun 10, 2022
- Abate by
- Jul 29, 2022
- Penalty
- Initial $2,486 · Current $1,243 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:(a) (LOCATION) (IDENTIFY EQUIPMENT AND CONDITION(S)) (STATE HAZARD(S) TO EMPLOYEE(S)) Location: 30-7 Powers Avenue, Meriden, CT 06451 - On or about December 23, 2021, the electrical outlet on the wall adjacent to the buffing machines was not equipped with a cover as the faceplate was broken.
Recent events (2)
- — I (S) $1243
- — Z (S) $2486
More inspections at BAR Plating, LLC
View BAR Plating, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332813)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345702906.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.