NEW RICHMOND, WI —
OSHA Inspection: ELLICOTT DREDGE TECHNOLOGIES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ELLICOTT DREDGE TECHNOLOGIES, LLC in 1750 MADISON AVENUE, NEW RICHMOND, WI 54017 (NAICS 333120). OSHA activity number 345704449.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELLICOTT DREDGE TECHNOLOGIES, LLC
- Site address
- 1750 MADISON AVENUE
- City
- NEW RICHMOND
- State
- WI
- ZIP
- 54017
- Mailing
- 1750 MADISON AVENUE, NEW RICHMOND, WI 54017
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 57
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 24, 2022
- Abate by
- Apr 14, 2022
- Penalty
- Initial $6,340 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Bay 3; The employer did not provide effective methods of machine guarding to protect employee(s) from pinch points created by the ram and die on the Cincinnati Press Brake (S/N 50006).
Recent events (2)
- — I (S) $0
- — Z (S) $6340
1910.305 G01 IV A
- Issued
- Feb 24, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Bay 3; An extension cord was used as permanent wiring to energize a Global brand 24" wall mounted fan (S/N 607050).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333120)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345704449.