Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADM, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADM, INC. in 1811 DOCK STREET, MEMPHIS, TN 38113 (NAICS 424510). OSHA activity number 345708754.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADM, INC. — free Get an email when a new federal OSHA severe-injury report for ADM, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ADM, INC.
Site address
1811 DOCK STREET
City
MEMPHIS
State
TN
ZIP
38113
Mailing
PO BOX 629, MARION, AR 72364
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
19
Ownership type
A

2 citations on file for this inspection.

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 9, 2022
Penalty
Initial $6,215 · Current $3,729 Reduced
29 CFR  1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   a)  Control Room, 1811 Dock Street, Memphis, TN.  On or about December 16, 2021, workers were exposed to a hazard of electric shock in that the cover was missing from electrical outlet used to supply power to a small refrigerator.
Recent events (2)
  • — I (S) $3729
  • — Z (S) $6215

1910.157 E01

Other-than-serious 1 instance 1 exposed
Issued
Feb 9, 2022
Abate by
Feb 15, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(1):The employer was not responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:  Control Room, 1811 Dock Street, Memphis, TN.  On or about December 16, 2021, workers were exposed to a fire hazard in that the employer did not inspect the fire extinguisher.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ADM, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345708754.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.