LEIPSIC, OH —
OSHA Inspection: PRO-TEC COATING COMPANY, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRO-TEC COATING COMPANY, LLC in 5500 PRO-TEC PARKWAY, LEIPSIC, OH 45856 (NAICS 332812). OSHA activity number 345710149.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRO-TEC COATING COMPANY, LLC
- Site address
- 5500 PRO-TEC PARKWAY
- City
- LEIPSIC
- State
- OH
- ZIP
- 45856
- Mailing
- 5500 PRO-TEC PARKWAY, LEIPSIC, OH 45856
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 405
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Feb 3, 2022
- Abate by
- Feb 16, 2022
- Penalty
- Initial $79,761 · Current $14,000 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the following elements and actions and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about January 1, 2022, employees were exposed to hydraulic pinch point hazards and crushing injury in that the cutting Continuous Annealing Line SMS ID Bander Machine was not locked out prior to employees troubleshooting the area of the machine's band feed and cutting blade area. The employer did not ensure that energy control application steps to control the mechanical, hydraulic, and pneumatic energy sources were implemented prior to servicing tasks - the employer did not: Ensure that equipment was turned off or shut down. Physically operate energy isolating devices to control energy sources and affix lockout device(s). Ensure that all potentially hazardous stored or residual energy was relieved, disconnected, and rendered safe. Verify that isolation and deenergization of the machine or equipment had been accomplished. Pro-Tec Coating Company, LLC was previously cited for a violation of this occupational safety and health standard (1910.147(d)), which was contained in OSHA inspection number 1488951, citation number one, item number one and was affirmed as a final order on October 16, 2020, with respect to a workplace located at 5500 Pro-Tec Parkway Leipsic OH 45856.
Recent events (2)
- — I (S) $14000
- — Z (R) $79761
More inspections at Pro-Tec Coating Company, LLC
View Pro-Tec Coating Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345710149.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.