SAINT FRANCIS, WI —
OSHA Inspection: ADVANCE SCREW PRODUCTS, INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADVANCE SCREW PRODUCTS, INCORPORATED in 3767 SOUTH KINNICKINNIC AVENUE, SAINT FRANCIS, WI 53235 (NAICS 332721). OSHA activity number 345714117.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCE SCREW PRODUCTS, INCORPORATED
- Site address
- 3767 SOUTH KINNICKINNIC AVENUE
- City
- SAINT FRANCIS
- State
- WI
- ZIP
- 53235
- Mailing
- 3767 SOUTH KINNICKINNIC AVENUE, SAINT FRANCIS, WI 53235
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C07 I
- Issued
- Mar 18, 2022
- Abate by
- May 4, 2022
- Penalty
- Initial $5,801 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: (a) On or about January 4, 2022, the employer failed to provide authorized employee training to screw machine operators prior to employees engaging in servicing and maintenance activities, such as (but not limited to) set-up operations.
Recent events (2)
- — I (S) $3500
- — Z (S) $5801
1910.147 D
- Issued
- Mar 18, 2022
- Abate by
- May 4, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) On or about January 4, 2022, the employer did not ensure employees implemented energy control procedures prior to entering the side box cam area on the New Britain, Model 51 screw machine to feel for the high point of slide cam. The machine was not isolated from all energy sources prior to engaging in these servicing and maintenance activities. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)], were not implemented to protect employees from the unexpected energization, startup, or release of stored energy during machine servicing and maintenance activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Advance Screw Products, Incorporated
View Advance Screw Products, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345714117.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.