OSHA Inspection: FGF BRAND LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FGF BRAND LLC in 122 STRIBLING, SAN ANTONIO, TX 78204 (NAICS 311811). OSHA activity number 345714992.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FGF Brand LLC — free Get an email when a new federal OSHA severe-injury report for FGF Brand LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FGF BRAND LLC
Site address
122 STRIBLING
City
SAN ANTONIO
State
TX
ZIP
78204
Mailing
145 EAST ZAVALLA ST., SAN ANTONIO, TX 78204
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311811
Employees
452
Ownership type
A

6 citations on file for this inspection.

1910.22 A03

Serious Gravity 1 2 instances 45 exposed
Issued
Mar 23, 2022
Penalty
Initial $6,215 · Current $2,500 Reduced
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  A)  On or about January 7, 2022, and at times prior thereto, employees were exposed to slip, trips, or fall hazards when working near electrical flexible cable on the floor of the depositing area.  B)  On or about January 7, 2022, and at times prior thereto, employees were exposed to slip, trips, or fall hazards when working near an airline on the floor of the depositing area.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $6215

1910.147 C07 I B

Other-than-serious Gravity 5 1 instance 45 exposed
Issued
Mar 23, 2022
Abate by
Apr 11, 2022
Penalty
Initial $8,287 · Current $2,500 Reduced
29 CFR  1910.147(c)(7)(i)(B): Affected employee(s) was not instructed in the purpose and use of the energy control procedure:  Depositing Area: On or about January 7, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while performing maintenance activities such as cleaning without being trained on lockout tagout procedures for affected employees.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $8287

1910.212 A01

Serious Gravity 10 12 instances 45 exposed
Issued
Mar 23, 2022
Abate by
Apr 25, 2022
Penalty
Initial $14,502 · Current $5,000 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks:   A)  Depositing Area: On or about January 7, 2022, and at times prior thereto, employees were exposed to an amputation hazard while working on the streusel cake conveyor line without guards at the pulley belt ingoing nip points where the conveyor changes belt types.  B)  Depositing Area: On or about January 7, 2022, and at times prior thereto, employees were exposed to an amputation hazard while working on the streusel cake conveyor line without affixed guards on the sides of the conveyor.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $14502

1910.219 C02 I

Serious Gravity 1 2 instances 45 exposed
Issued
Mar 23, 2022
Abate by
Apr 25, 2022
Penalty
Initial $6,215 · Current $2,500 Reduced
29 CFR  1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  A-B) Depositing Area: On or about  January 7, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while working around the streusel depositor with unguarded rotating shafts.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $6215

1910.219 C04 I

Serious Gravity 1 2 instances 45 exposed
Issued
Mar 23, 2022
Abate by
Apr 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.219(c)(4)(i):Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  A-B) Depositing Area: On or about  January 7, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while working around the streusel depositor with unguarded rotating shafts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 A02 XI

Serious Gravity 1 1 instance 45 exposed
Issued
Mar 23, 2022
Penalty
Initial $6,215 · Current $2,500 Reduced
29 CFR  1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage:   On or about January 7, 2022, and at times prior thereto, employees were exposed to an electrical hazard when stepping over an electrical flexible cable on the floor of the depositing area.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $6215

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345714992.