On , OSHA opened a referral safety inspection of SENECA FOODS CORPORATION in 100 GAMBEE ROAD, GENEVA, NY 14456 (NAICS 311421). OSHA activity number 345716443.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SENECA FOODS CORPORATION
- Site address
- 100 GAMBEE ROAD
- City
- GENEVA
- State
- NY
- ZIP
- 14456
- Mailing
- 100 GAMBEE ROAD, GENEVA, NY 14456
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311421
- Employees
- 194
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 C
- Issued
- Jun 27, 2022
- Penalty
- Initial $9,116 · Current $9,116
General-duty citation text
29 CFR 1910.22(c): 29 CFR 1910.22(c): The employer did not provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces. (a) On or about February 2nd, 2022, employees were not protected from tripping hazards while walking over the conveyor belt in the Glass Line labeling and packaging room.
Recent events (2)
- — I (O) $9116
- — Z (S) $9116
1910.146 D09
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $14,502 · Current $11,602 Reduced
General-duty citation text
29 CFR 1910.146(d)(9):The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry (a) On or about 28 January 2022, and in times prior thereto, the employer did not develop procedures for rescuing employees from permit required confined spaces while clearing jams inside of cooker shells
Recent events (2)
- — I (S) $11601.6
- — Z (S) $14502
1910.146 K01 I
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(k)(1)(i):The employer did not ensure that each member of the rescue service was provided with, and trained to use properly the personal protective equipment and rescue equipment necessary for making rescues from permit spaces: (a) On or about 28 January 2022, and in times prior thereto, the employer did not coordinate with the identified rescue service to ensure that said service was trained for rescue of entrants from permit required confined spaces while clearing jams inside of cooker shells
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 K02 IV
- Issued
- Jun 27, 2022
- Abate by
- Aug 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(k)(2)(iv):The employer did not ensure that affected employees practice making permit space rescues at least once every 12 months, by means of simulated rescue operations in which they remove dummies, manikins, or actual persons from the actual permit spaces or from representative permit spaces: (a) On or about 28 January 2022, and in times prior thereto, the employer did not practice procedures for rescuing employees from permit required confined spaces while inside of cooker shells
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F01 II
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1910.147(f)(1)(ii):When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to the paragraph (e)(2): (a) On or about 28 December 2021, during test run of a green bean cutting machine, employees were not removed from hazards of rotating parts at the Urschel Model 30 Bean Cutter
Recent events (2)
- — I (S) $14502
- — Z (S) $14502
1910.147 F03 II
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $14,502 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii):Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4): (a) On or about 28 December 2021, and at times prior thereto, an authorized employee did not affix lockout/tagout devices to the energy isolating device at the Model 30 cutting bowl while performing maintenance
Recent events (2)
- — I (S) $0
- — Z (S) $14502
1910.212 A01
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $14,502 · Current $11,602 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 2 Februrary 2022, and in times prior thereto, employees in the welding shop were not protected from laceration, pinching, and caught in hazards from a rotating chuck, drill bit, and drive shaft on a Clausing drill press.
Recent events (2)
- — I (S) $11601.6
- — Z (S) $14502
1910.37 A04
- Issued
- Jun 27, 2022
- Abate by
- Jul 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: (a) On or about February 2nd, 2022, the exit sign on the second floor of the sauerkraut tank farm was not illuminated, nor was the emergency flood light in working order
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Jun 27, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) In the warehousing area, metal racks were stored in front of the NEMA 12 enclosure for CB panel #10 fed from PP17
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Seneca Foods Corporation