Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUM LAUDE GROUP, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUM LAUDE GROUP, INC. in 1 OVERLOOK ROAD, SCARSDALE, NY 10583 (NAICS 236115). OSHA activity number 345720387.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CUM Laude Group, INC. — free Get an email when a new federal OSHA severe-injury report for CUM Laude Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 OVERLOOK ROAD
City
SCARSDALE
State
NY
ZIP
10583
Mailing
14 GORHAM RD., SCARSDALE, NY 10583
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.300 A

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 2, 2022
Penalty
Initial $4,351 · Current $2,727 Reduced
29 CFR  1926.300(a):Hand tool(s), power tool(s) or similar equipment were not maintained in a safe condition:  On or about: January 11, 2022 Location: 1 Overlook rd. Scarsdale NY, 10583  a) Makita circular saw was not maintained in safe condition due to fray wires being taped. Employees were expose to electric shock hazard.
Recent events (3)
  • — C (S) $4351
  • — F (S) $2727
  • — Z (S) $4351

1926.403 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 2, 2022
Penalty
Initial $7,252 · Current $4,546 Reduced
29 CFR  1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:   On or about: January 11, 2022 Location: 1 Overlook rd. Scarsdale NY, 10583  a)  2-Gangway box with outlets and extension cord was not approved to be used as relocatable power tap to connect equipment. Employees were exposed electric shock hazards.
Recent events (3)
  • — C (S) $7252
  • — F (S) $4546
  • — Z (S) $7252

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 2, 2022
Penalty
Initial $4,351 · Current $2,727 Reduced
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   On or about: January 11, 2022 Location: 1 Overlook rd. Scarsdale NY, 10583  a) Extension cord connected to Makita circular saw had damaged insulations with exposed internal wires due to strain. Employees were exposed to electrical shock hazard.
Recent events (3)
  • — C (S) $4351
  • — F (S) $2727
  • — Z (S) $4351

View CUM Laude Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345720387.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.