Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILLER ELECTRIC MFG. LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MILLER ELECTRIC MFG. LLC in 1635 WEST SPENCER STREET, APPLETON, WI 54912 (NAICS 333992). OSHA activity number 345728620.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miller Electric MFG. LLC — free Get an email when a new federal OSHA severe-injury report for Miller Electric MFG. LLC is published. One employer, no account, unsubscribe in one click.
Site address
1635 WEST SPENCER STREET
City
APPLETON
State
WI
ZIP
54912
Mailing
1635 WEST SPENCER STREET, APPLETON, WI 54912
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
754
Ownership type
A

4 citations on file for this inspection.

1910.119 D03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2022
Abate by
Jun 30, 2022
Penalty
Initial $8,806 · Current $6,164 Reduced

Hazardous substances 0170

29 CFR  1910.119(d)(3)(ii):  The employer shall document that equipment complies with recognized and generally accepted good engineering practices:  At an establishment located at 1635 West Spencer Street in Appleton, Wisconsin; the employer did not document that the Ice House emergency stop control system complies with recognized and generally accepted good engineering practices (RAGEGEP). The employer failed to document compliance with their chosen RAGEGEP including IIAR 9, when an E-Stop push-button and emergency ventilation control switch were not located outside the machinery room and adjacent to the designed principal engine room door. This hazardous condition potentially exposed employees to inhalation and burn hazards from ammonia liquid and vapors.
Recent events (2)
  • — I (S) $6164.2
  • — Z (S) $8806

1910.119 F01 I D

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2022
Abate by
Jun 1, 2022
Penalty
Initial $8,806 · Current $6,164 Reduced

Hazardous substances 0170

29 CFR 1910.119(f)(1)(i)(D): The employer shall develop and implement written operating procedures that provide clear instructions and shall address steps for each operating phase including emergency shutdown including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner:  At an establishment located at 1635 West Spencer Street in Appleton, Wisconsin; the employer's operating procedure addressing the Emergency Shutdown operating phase did not include the conditions under which emergency shutdown is required. The standard operating procedure "Ammonia Refrigeration System" did not contain descriptions, limitations, conditions or situations which would require HVAC employees to trigger an emergency shutdown of the ammonia refrigeration system.
Recent events (2)
  • — I (S) $6164.2
  • — Z (S) $8806

1910.119 J02

Serious Gravity 5 4 instances 2 exposed
Issued
Apr 22, 2022
Abate by
Jun 1, 2022
Penalty
Initial $8,806 · Current $0 Reduced

Hazardous substances 0170

29 CFR 1910.119(j)(2): The employer shall establish and implement written procedures to maintain the on-going integrity of process equipment:  At an establishment located at 1635 West Spencer Street in Appleton, Wisconsin; the employer did not establish or implement written procedures to maintain the on-going integrity of process equipment. The employer did not develop written procedures of sufficient detail to provide to the employers' inspectors (including contract inspectors) instruction on how to conduct inspection and test of the process equipment when:  a)  Basset Mechanical conducted annual mechanical integrity inspections on ammonia process equipment such as, but not limited to exhaust fans, the ammonia detector system, the control system, compressors, valves, and piping/vessels along with their respective insulation.  b)  Basset Mechanical and Miller Electric employee conducted monthly mechanical integrity inspection on ammonia process equipment such as, but not limited to compressors, vessels, pumps, and condensers.  c)  Basset Mechanical and a subcontractor (Janx Inspection most recently) conducted independent periodic corrosion under insulation (CUI) inspections of piping and vessels.  d)  Miller Electric employees conducted daily mechanical inspection on ammonia process equipment such as, but not limited to system pressures, compressors, vessels, pumps and heat exchangers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8806

1910.119 J04 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2022
Abate by
Jun 1, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 0170

29 CFR 1910.119(j)(4)(iv): The employer shall document each inspection and test that has been performed on process equipment. The documentation shall identify the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test:   At an establishment located at 1635 West Spencer Street in Appleton, Wisconsin; the employer did not document each inspection that had been performed on the Ammonia Refrigeration System's (ARS) process equipment. Employees conducted daily inspections of the ARS's compressors, pumps, vessels, and heat exchangers. However, employees were only required to document the daily inspections on Mondays, Wednesdays, and Fridays on the "Miller Electric System Log Sheet". Employees were not documenting every daily inspection they conducted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345728620.