PASKENTA, CA —
OSHA Inspection: USDA, MENDOCINO NATIONAL FOREST, PASKENTA WORK CENTER
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USDA, MENDOCINO NATIONAL FOREST, PASKENTA WORK CENTER in 13280 PASKENTA ROAD, PASKENTA, CA 96074 (NAICS 115310). OSHA activity number 345729859.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 13280 PASKENTA ROAD
- City
- PASKENTA
- State
- CA
- ZIP
- 96074
- Mailing
- 100250 ELK MOUNTAIN ROAD, UPPER LAKE, CA 95485
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115310
- Employees
- 100
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.37 A01
- Issued
- Mar 14, 2022
- Abate by
- Apr 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(1): Exit routes shall not have flammable, explosive, combustible gases or flammable furnishings stored in the exit route. Paskenta Work Center, Maintenance Shop: Oxygen and Acetylene cylinders were stored near a designated exit.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Mar 14, 2022
- Abate by
- Apr 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet. Paskenta Work Center, Maintenance Shop: The employer did not store two oxygen gas cylinders 20 feet apart from two flammable acetylene cylinders.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Mar 14, 2022
- Abate by
- Apr 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listed or labeling: Paskenta Work Center, Maintenance Shop: A 4 inch metal receptacle box with knockouts designated for fixed location was wired with a black flexible cord with plug and being utilized as an extension cord. Employees were exposed to electrical hazards.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Mar 14, 2022
- Abate by
- Apr 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Paskenta Work Center, Maintenance Shop: A 240 volts electrical service panel had unused circuit breaker opening that was not effectively closed. Employees were exposed to electrical hazards.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 115310)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345729859.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.