OSHA Inspection: 1KB & MS LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of 1KB & MS LLC in 1 KIEFFER LANE, KINGSTON, NY 12401 (NAICS 327331). OSHA activity number 345731996.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 1KB & MS LLC for free Get an email when a new federal OSHA severe-injury report for 1KB & MS LLC is published. One employer, no account, unsubscribe in one click.
Establishment
1KB & MS LLC
Site address
1 KIEFFER LANE
City
KINGSTON
State
NY
ZIP
12401
Mailing
1 KIEFFER LANE, KINGSTON, NY 12401
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
327331
Employees
47
Ownership type
Private (A)

3 citations on file for this inspection.

1910.29 B01

Deleted Repeat Gravity 5 1 instance 5 exposed
Issued
Jul 12, 2022
Penalty
Initial $15,954 · Current $0 Reduced
29 CFR  1910.29(b)(1): The employer did not ensure that  guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, that are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface:  a) At site, 2nd floor Hoist Area - On or about January 18, 2022 and at times prior thereto, employees were exposed to fall hazards of approximately 10 feet due to a guardrail system guarding the hoist area opening that did not have a top rail of 42 inches plus or minus 3 inches.  The 1KB & MS LLC, dba Kingston Block & Masonry LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1910.29(b)(1), which was contained in OSHA inspection number 1240159, citation number 1, item number 1b and was affirmed as a final order on June 14, 2019, with respect to a workplace located at 1 Kieffer Lane, Kingston, NY 12401.
Recent events (3)
  • · F (R) $0
  • · C (R) $15954
  • · Z (R) $15954

1910.147 C01

Serious Gravity 10 4 instances 4 exposed
Issued
Jul 12, 2022
Abate by
Jul 20, 2022
Penalty
Initial $22,333 · Current $11,166 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   a) At site, Block Plant Area - On or about January 18, 2022 and at times prior thereto, employees perform service and maintenance activities on Block Machine 1 (Manufactured by BESSER CO., Serial No. 1336, Model No. PRC86-R4). The employer does not have and/or follow an adequate lockout/tagout program consisting of an energy control procedure, employee training and periodic inspection.  b) At site, Block Plant Area - On or about January 18, 2022 and at times prior thereto, employees perform service and maintenance activities on Block Machine 2 (BESSER).  The employer does not have and/or follow an adequate lockout/tagout program consisting of an energy control procedure, employee training and periodic inspection.  c) At site, 2nd Floor Mixer Area - On or about January 18, 2022 and at times prior thereto, employees perform service and maintenance activities on Mixer 1/B.  The employer does not have and/or follow an adequate lockout/tagout program consisting of an energy control procedure, employee training and periodic inspection.  d) At site, 2nd Floor Mixer Area - On or about January 18, 2022 and at times prior thereto, employees perform service and maintenance activities on Mixer 2/A.  The employer does not have and/or follow an adequate lockout/tagout program consisting of an energy control procedure, employee training and periodic inspection.  The 1KB & MS LLC, dba Kingston Block & Masonry LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1910.147(c)(1), which was contained in OSHA inspection number 1240159, citation number 1, item number 2 and was affirmed as a final order on June 14, 2019, with respect to a workplace located at 1 Kieffer Lane, Kingston, NY 12401.
Recent events (4)
  • · P (S) $11166
  • · F (S) $11166
  • · C (R) $22333

1910.305 G01 IV A

Repeat 1 instance 4 exposed
Issued
Jul 12, 2022
Penalty
Initial $319 · Current $160 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) At site, 2nd Floor Mixing Area - On or about July 12, 2017, an extension cord powering equipment was being used as permanent wiring.  The 1KB & MS LLC, dba Kingston Block & Masonry LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 1240159, citation number 2, item number 8 and was affirmed as a final order on June 14, 2019, with respect to a workplace located at 1 Kieffer Lane, Kingston, NY 12401.
Recent events (3)
  • · F (R) $160
  • · C (R) $319
  • · Z (R) $319

View 1KB & MS LLC's full OSHA safety record →