Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WELDFIT CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WELDFIT CORPORATION in 4135 DAYCO ST., HOUSTON, TX 77092 (NAICS 333249). OSHA activity number 345732523.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Weldfit Corporation — free Get an email when a new federal OSHA severe-injury report for Weldfit Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
WELDFIT CORPORATION
Site address
4135 DAYCO ST.
City
HOUSTON
State
TX
ZIP
77092
Mailing
4133 SOUTHERLAND RD., HOUSTON, TX 77092
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
40
Ownership type
A

3 citations on file for this inspection.

1910.184 I09 III

Other-than-serious Gravity 5 1 instance 40 exposed
Issued
Mar 28, 2022
Penalty
Initial $5,801 · Current $4,641 Reduced
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service:  On or about January 18, 2022 employees were exposed to struck-by hazards while using a damaged synthetic web sling that was not immediately removed from service.
Recent events (2)
  • — I (O) $4640.8
  • — Z (S) $5801

1910.305 G01 IV A

Other-than-serious Gravity 5 1 instance 40 exposed
Issued
Mar 28, 2022
Abate by
Apr 20, 2022
Penalty
Initial $7,252 · Current $5,802 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about January 18, 2022 employees were exposed to electrical hazards while working on a manual lathe that had a flexible cord used as a substitute for fixed wiring.
Recent events (2)
  • — I (O) $5801.6
  • — Z (S) $7252

1910.1200 F06 I

Other-than-serious 1 instance 40 exposed
Issued
Mar 28, 2022
Abate by
Apr 1, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(i):  Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v)  On or about January 18, 2022 employees were working with chemicals in secondary containers that were not adequately labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Weldfit Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345732523.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.