Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PILGRIM'S PRIDE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PILGRIM'S PRIDE CORPORATION in 654 UNIVETER ROAD, CANTON, GA 30115 (NAICS 311615). OSHA activity number 345734966.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pilgrim'S Pride Corporation — free Get an email when a new federal OSHA severe-injury report for Pilgrim'S Pride Corporation is published. One employer, no account, unsubscribe in one click.
Site address
654 UNIVETER ROAD
City
CANTON
State
GA
ZIP
30115
Mailing
654 UNIVETER ROAD, CANTON, GA 30115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311615
Employees
675
Ownership type
A

9 citations on file for this inspection.

1910.22 D01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $9,116 · Current $8,031 Reduced
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition:  a) Plant; on or about January 19, 2022 and at times prior to, employees accessing the roof  of the Debone engine room were exposed to trip/fall hazards, in that the employer did not ensure that  missing platform grates were installed, and broken sections were repaired/replaced.
Recent events (3)
  • — F (O) $8031
  • — C (S) $9116
  • — Z (S) $9116

1910.37 B02

Deleted Serious Gravity 10 1 instance 14 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Plant, Fresh Shipping Dock area; on or about January 19, 2022 and at times prior to, employees were exposed to fire and/or anhydrous ammonia hazards,  in that the employer did not ensure that the exit door discharging to the battery room  was marked by  an EXIT sign to minimize delays and exposure during an emergency.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.37 B06

Other-than-serious Gravity 10 1 instance 14 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $13,417 Reduced
29 CFR  1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a) Debone Area, Fresh Shipping Dock area; on or about January 19, 2022 and at times prior to, employees were exposed  to fire and/or anhydrous ammonia hazards, in that the employer did not ensure that the exit door  on the dock side  (discharging towards the stairs) was illuminated and distinctive in color in order to minimize delays and exposure during an emergency.
Recent events (3)
  • — F (O) $13417
  • — C (S) $14502
  • — Z (S) $14502

1910.119 D03 I H

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.119(d)(3)(i)(H):Process safety information pertaining to the equipment in the process did not include the safety systems:  a) Plant, Debone Area; on or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that the employer did not document Process Safety Information pertaining to the equipment safety systems such as, but not limited to, ammonia system emergency stop devices and, operational safeties for compressors DSCH3 and DSCH4 including, switches, sensors, detectors, alarms, and related components.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.119 I02 I

Other-than-serious Gravity 10 1 instance 10 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $13,417 Reduced
29CFR 1910.119(i)(2)(i): The employer did not perform a pre-startup safety review to confirm that construction and equipment is in accordance with design specifications.  b) Plant, Debone Engine Room entrance area; on or about January 19, 2022 and at times prior to, the employer failed to document compliance with recognized and generally accepted good engineering practices to protect employees exposed to anhydrous ammonia hazards as specified in ANSI/IIAR 2-2014 Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems, Section 7.2.4, which requires "Equipment shall be  protected where a risk of physical damage exists. Where equipment containing ammonia is in an area with heavy vehicular traffic during normal operations and a risk of impact exists, vehicle barriers or alternative protection shall be provided in accordance with the Fire Code."  The employer did not protect the DHTA/DLTA high temperature accumulator  and piping  from vehicles,  to prevent damage or rupture and loss of containment of 9,145 lb. of anhydrous ammonia.
Recent events (3)
  • — F (O) $13417
  • — C (S) $14502
  • — Z (S) $14502

1910.119 F01 II B

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.119(f)(1)(ii)(B):The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information, and did not address the steps required to correct or avoid deviation.  a) On or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that written operating procedures for the DECD1 and DECD2 evaporative condensers did not contain clear instructions on steps required to correct or avoid deviation.
Recent events (3)
  • — F (S) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.119 I02 II

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.119(i)(2)(ii):  Safety, operating, maintenance, and emergency procedures were not adequate:    a) On or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that the employer did not confirm through a pre-startup safety  review that the  written operation procedures for the DECD1 and DECD2  evaporative condensers  contained clear instructions/warnings for manual operation.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.119 I02 I

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.119(i)(2)(i):  Construction and equipment was not in accordance with design specifications:  a) Plant, Debone area; on or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that the employer did not perform tests and inspections on emergency stop devices to ensure the equipment  was in accordance with design specifications and operable in case of emergency.  c) Plant, Debone area; on or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that the employer did not perform tests and inspections on the critical limiting devices (operational safeties) for compressors DSCH3 and DHCH4 to ensure the equipment was in accordance with design specifications to prevent worker exposure to an accidental anhydrous ammonia release and damage to equipment.
Recent events (3)
  • — F (S) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.120 Q03 IV

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2022
Abate by
Aug 25, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.120(q)(3)(iv):Employees engaged in emergency response and exposed to hazardous substances presenting an inhalation hazard or potential inhalation hazard, did not wear positive-pressure self-contained breathing apparatus until such time that the individual in charge of the incident command system determined through the use of air monitoring that a decreased level of respiratory protection would not result in hazardous exposures to employees:  a) Plant, Debone area; on or about January 19, 2022, employees were exposed to anhydrous ammonia hazards, in that the employer did not ensure that  each emergency responder intending to reach the king valve and emergency stops was protected by  a positive pressure self-contained breathing apparatus until air monitoring would indicate that a lower level of respiratory protection would not result in hazardous exposure.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

View Pilgrim'S Pride Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345734966.