OSHA Inspection: MASS HOME REMODELING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MASS HOME REMODELING, INC. in 63-65 MERRIAM ST, SOMERVILLE, MA 02143 (NAICS 236115). OSHA activity number 345736763.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mass Home Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for Mass Home Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
63-65 MERRIAM ST
City
SOMERVILLE
State
MA
ZIP
02143
Mailing
77 BEAVER STREET, MILFORD, MA 01757
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
11
Ownership type
A

9 citations on file for this inspection.

1926.451 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $2,900 Reduced
29 CFR  1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, the employer allowed employees to work from a pump jack scaffold with 2x8 in planks containing knots and other imperfections. These scaffold planks were not graded by a recognized lumber grading association for this use and were not capable of supporting 4 times the maximum intended load.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $5801

1926.451 B02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.451(b)(2)(i): Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold was not at least 12 inches (30 cm) wide.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees working from a pump jack scaffold were not protected from fall hazards where the scaffold platforms were less than 12 inches wide. The employer was using 2x8 nominal wood planks for scaffold platforms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.451 B05 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees working from a pump jack scaffolds were not protected from fall hazards where the scaffold platform extended more than 18 inches beyond a support.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.451 B07

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap did not occur only over supports.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees were exposed to fall hazards while working from a pump jack scaffold that did not have the work platforms bridged over a support.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.451 F03

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Abate by
Jul 8, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, a pump jack scaffold and its components were not inspected by a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.451 F07

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Abate by
Jul 8, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, a pump jack scaffolding was erected and moved by employees that were not qualified as competent persons.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.451 G01

Serious Gravity 10 2 instances 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $2,900 Reduced
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees working from a pump jack scaffold were exposed to fall hazards of 30 feet or greater in the following instances:  a) employees were not protected from falling where mid-rails were missing from the pump jack scaffold. b) employees were not protected from falling where end-rails were missing from the pump jack scaffold.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $5801

1926.452 J02

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees were exposed to fall hazard while working on pump jack scaffolding that only had triangular bracing installed at the top.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 3, 2022
Penalty
Initial $5,801 · Current $2,900 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b).  (a) Location - 63-65 Merriam Street, Somerville, MA:  On or about 1/19/2022, employees were exposed to fall hazards greater than 30 feet while working on a low-sloped roof with no means of fall protection.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $5801