Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: W. BAKER MANAGEMENT INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W. BAKER MANAGEMENT INC. in 664 LOCHGELLY RD., LOCHGELLY, WV 25866 (NAICS 332710). OSHA activity number 345737282.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W. Baker Management INC. — free Get an email when a new federal OSHA severe-injury report for W. Baker Management INC. is published. One employer, no account, unsubscribe in one click.
Site address
664 LOCHGELLY RD.
City
LOCHGELLY
State
WV
ZIP
25866
Mailing
P.O. BOX 936, BECKLEY, WV 25801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
11
Ownership type
A

2 citations on file for this inspection.

1910.28 B11 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 9, 2022
Penalty
Initial $3,698 · Current $2,218 Reduced
29 CFR 1910.28(b)(11)(i): Each employee exposed to an unprotected side or edge of a stairway landing that was 4 feet (1.2 m) or more above a lower level was not protected by a guardrail or stair rail system:  (a)  Mezzanine Storage Area:  On January 20, 2022, and times prior, employees access a stairway landing that was 9 feet 3 inches above ground level that was not equipped with an adequate guardrail system, in that it was not equipped with an intermediate railing.    Abatement Note:  Guardrail systems must meet the design criteria listed in 29 CFR 1910.29(b).
Recent events (2)
  • — I (S) $2218
  • — Z (S) $3698

1910.29 F04

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 9, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4): Openings in a stair rail system exceeded 19 inches at its least dimension:  (a)  Maintenance Area:  On January 20, 2022, and times prior, employees access a stairway that had an opening of 32 inches in the stair rail system on the open side.     Abatement Note:  Stair rail systems must meet the design criteria listed in 29 CFR 1910.29(f).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View W. Baker Management INC.'s full OSHA safety record →