ERIE, CO —
OSHA Inspection: VM CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VM CONSTRUCTION in 356 LOWE WAY, ERIE, CO 80514 (NAICS 238170). OSHA activity number 345738090.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VM CONSTRUCTION
- Site address
- 356 LOWE WAY
- City
- ERIE
- State
- CO
- ZIP
- 80514
- Mailing
- 993 DAWSON STREET, AURORA, CO 80011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G04 I
- Issued
- Feb 25, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms. (a) Location - 356 Lowe Way, Erie, CO On or about 01/20/2022, employee was engaged in siding activities on pump jack scaffolding with no end rail protection, subjecting the employee to fall hazards of greater than 10 feet.
Recent events (1)
- — Z (S) $4351
1926.452 J02
- Issued
- Feb 25, 2022
- Abate by
- May 4, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a) Location - 356 Lowe Way, Erie, CO On or about 01/20/2022, employee was engaged in siding activities on pump jack scaffolding with only one rigid triangular brace on each pole.
Recent events (1)
- — Z (S) $0
More inspections at VM Construction
View VM Construction's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345738090.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.