Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNRUN INSTALLATION SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUNRUN INSTALLATION SERVICES, INC. in 43 BEDFORD ST., BURLINGTON, MA 01803 (NAICS 237130). OSHA activity number 345750160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrun Installation Services, INC. — free Get an email when a new federal OSHA severe-injury report for Sunrun Installation Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
43 BEDFORD ST.
City
BURLINGTON
State
MA
ZIP
01803
Mailing
1800 WEST ASHTON BLVD, LEHI, UT 84043
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
3891
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Repeat Gravity 10 1 instance 1 exposed
Issued
Jul 7, 2022
Penalty
Initial $79,761 · Current $95,000
29 CFR  1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:   Location - 43 Bedford St. Burlington, MA  On or about 1/27/2022, the employer did not ensure employees were protected from being struck in the head from falling tools, equipment solar panel parts while working on the ground and from ladders below the workers installing the solar panel system on the roof.  The Vivint Solar, Inc. dba Sunrun Solar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 1543185, citation number 1, item number 1 and was affirmed as a final order on January 6, 2022, with respect to a workplace located at 29 S Bedford St. Woburn, MA 01801.
Recent events (2)
  • — I (R) $95000
  • — Z (R) $79761

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 7, 2022
Penalty
Initial $145,027 · Current $10,000 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  Location - 43 Bedford St. Burlington, MA  On or about 1/27/2022, the employer did not ensure employees installing a solar panel system on a residential dwelling were protected from falls to a lower level.  The Vivint Solar, Inc. dba Sunrun Solar was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1543185, citation number 2, item number 1 and was affirmed as a final order on January 6, 2022, with respect to a workplace located at 29 S Bedford St. Woburn, MA 01801.  The Sunrun Solar, Inc. company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1342329,  citation number 1, item number 1 and was affirmed as a final order on March 12, 2019, with respect to a workplace located at 63-19 90th Street, Howard Beach, NY 11414.
Recent events (2)
  • — I (S) $10000
  • — Z (R) $145027

1904.40 A

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jul 7, 2022
Abate by
Aug 23, 2022
Penalty
Initial $2,279 · Current $0 Reduced
29 CFR  1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  Location - 230 Ballardvale St Suite E Wilmington, MA  On or about 4/8/2022, the employer did not provide all OSHA logs or equivalent fours hours after the request was made.
Recent events (2)
  • — I (O) $0
  • — Z (O) $2279

View Sunrun Installation Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345750160.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.