WASHINGTON, DC ·
OSHA Inspection: MARALY CONSTRUCTION COMPANY, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of MARALY CONSTRUCTION COMPANY, INC. in 1201 NEW YORK AVE., NW, WASHINGTON, DC 20005 (NAICS 337110). OSHA activity number 345750665.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARALY CONSTRUCTION COMPANY, INC.
- Site address
- 1201 NEW YORK AVE., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20005
- Mailing
- 13200 WILTON OAK DR., SILVER SPRING, MD 20906
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 7
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.403 D01
- Issued
- Jul 20, 2022
- Abate by
- Aug 4, 2022
- Penalty
- Initial $1,585 · Current $1,585
General-duty citation text
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: (a) Third Floor - On or about January 20, 2022, cabinet installers were exposed to an electrical contact hazard from the live parts of a 120-volt duplex outlet box which was not mounted upon a vertical surface as designed. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $1585
1926.403 I02 I
- Issued
- Jul 20, 2022
- Abate by
- Aug 4, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: (a) Third Floor - On or about January 20, 2022, cabinet installers were exposed to an electrical contact hazard from the live parts of a 120-volt duplex outlet box which was not completely covered. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $0
1926.405 G02 IV
- Issued
- Jul 20, 2022
- Abate by
- Aug 4, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Third Floor - On or about January 20, 2022, cabinet installers were exposed to an electrical contact hazard from the live parts of a 120-volt duplex outlet box was not provided with strain relief.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 337110)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345750665.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.