Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RICHARD'S ELECTRIC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RICHARD'S ELECTRIC in 5639 RIM PASS, SAN ANTONIO, TX 78257 (NAICS 238210). OSHA activity number 345751457.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Richard'S Electric — free Get an email when a new federal OSHA severe-injury report for Richard'S Electric is published. One employer, no account, unsubscribe in one click.
Establishment
RICHARD'S ELECTRIC
Site address
5639 RIM PASS
City
SAN ANTONIO
State
TX
ZIP
78257
Mailing
6138 UPWOOD DRIVE, SAN ANTONIO, TX 78238
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 21, 2022
Penalty
Initial $2,486 · Current $0 Reduced
29 CFR  1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  5639 Rim Pass:  On or about January 26, 2022, an employee was exposed to a fall hazard, while performing electrical work from the platform of an aerial lift, without being effectively trained to recognize and avoid the hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2486

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2022
Penalty
Initial $3,108 · Current $1,600 Reduced
29 CFR  1926.453(b)(2)(v):  A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e):  5639 Rim Pass:  On or about January 26, 2022, an employee was exposed to a fall hazard while performing work from the basket of an aerial lift, without using fall protection.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $3108

View Richard'S Electric's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345751457.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.