Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED STATES POSTAL SERVICE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of UNITED STATES POSTAL SERVICE in 500 QUIGLEY BLVD, NEW CASTLE, DE 19720 (NAICS 491110). OSHA activity number 345755185.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United States Postal Service — free Get an email when a new federal OSHA severe-injury report for United States Postal Service is published. One employer, no account, unsubscribe in one click.
Site address
500 QUIGLEY BLVD
City
NEW CASTLE
State
DE
ZIP
19720
Mailing
500 QUIGLEY BLVD, NEW CASTLE, DE 19720
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
500
Ownership type
A

8 citations on file for this inspection.

1910.22 D02

Other-than-serious Gravity 10 2 instances 50 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $12,327 · Current $6,000 Reduced
29 CFR  1910.22(d)(2): The employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again. The employer did not ensure that if the correction or repair cannot be made immediately, the hazard is guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired.  147  Quigley Blvd   New Castle, DE: 147 Quigley Blvd New Castle, DE: On or about February 1, 2022, the employer did not ensure hazardous conditions within the registry room were corrected or repaired when employees worked where the floors had compressor oil and water from a heating ventilation and air condition [HVAC] unit that routinely leaks on the floor and desk of the processing clerk.
Recent events (3)
  • — F (O) $6000
  • — C (S) $12327
  • — Z (S) $12327

1910.141 A04 II

Other-than-serious Gravity 1 4 instances 200 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $5,283 · Current $2,000 Reduced
29 CFR  1910.141(a)(4)(ii): Wastes were not collected and removed as often as necessary to maintain the place of employment in a sanitary condition:  a) 147 Quigley Blvd  New Castle, DE - On or about February 1, 2022, CSHO observed housekeeping conditions that were  inadequate within the men's and women's facilities [e.g. Locker Rooms-N170 and N171 respectively ] where fecal matter and urine were not regularly cleaned but were provided for employee use.
Recent events (3)
  • — F (O) $2000
  • — C (S) $5283
  • — Z (S) $5283

1910.147 C02

Deleted Serious Gravity 10 7 instances 7 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $12,327 · Current $0 Reduced
29 CFR  1910.147(c)(2): (i) If an energy isolated device in not capable of being locked out the employer's energy control program under paragraph (c)(1) of this section shall utilize a tagout system.   a) 147 Quigley Blvd New Castle, DE: On or about February 1, 2022,  the employer failed to ensure an orderly and safe shut down of  Hamper Dumpers numbers 10 and 11  which had broken shut off switches prior to servicing it.  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], stored energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to safeguard employees from the machine servicing hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $12327
  • — Z (S) $12327

1910.147 C04 I

Serious Gravity 10 7 instances 7 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $0 · Current $6,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) 147 Quigley Blvd New Castle, DE: On or about  January 28, 2022, the employer failed to ensure that lockout procedures were  properly utilized during the servicing and maintenance activities performed by trained and authorized mechanics on the Bundle Sorter, the Digital Barcode Sorter, the Automated Flat and the Hamper Dumpers number 10 and 11.
Recent events (3)
  • — F (S) $6000
  • — C (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 7 instances 7 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a) 147 Quigley Blvd New Castle, DE: On or about February 1, 2022, the employer failed to ensure a review of the developed written energy control procedure was conducted annually.   Abatement Note:    1.  Where lockout should be used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.1910.147(c)(6)(i)(D)   2.  Where tagout  should be used for energy control, the periodic inspection shall include a review, between the inspector and each authorized and affected employee, of that employee's responsibilities under the energy control procedure being inspected, and the elements set forth in paragraph (c)(7)(ii) of this section.1910.147(c)(6)(ii)   3.  The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I A

Deleted Serious Gravity 10 6 instances 500 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate:  a) 147 Quigley Blvd New Castle, DE: On or about January 28, 2022, the employer failed to ensure that employees engaged in servicing and maintenance of equipment were trained in the recognition of applicable hazardous energy sources, the type and magnitude of energy available in the workplace, and the methods and means necessary for energy isolation.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D01

Deleted Serious Gravity 10 7 instances 7 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $12,327 · Current $0 Reduced
29 CFR 1910.147(d)(1): Preparation for shutdown. Before an authorized or affected employee turns off a machine or equipment, the authorized employee shall have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy.  a) 147 Quigley Blvd New Castle, DE: On or about February 1, 2022, the employer failed to properly prepare or shut down the equipment prior to servicing or performing repair. The authorized employee attempting to de-energize the machine was not initially able to properly  control the hazardous energy stored in the equipment because of the emergency stop switch were  broken on Hamper Dumpers 10 and 11.
Recent events (3)
  • — F (S) $0
  • — C (S) $12327
  • — Z (S) $12327

1910.303 G01

Serious Gravity 5 7 instances 7 exposed
Issued
Jul 29, 2022
Abate by
Aug 24, 2022
Penalty
Initial $8,806 · Current $4,000 Reduced
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) 147 Quigley Blvd New Castle, DE: On or about February 1, 2022, employees were exposed to hazards due to the access and working space around the 240 volt electrical panels where the employees stored combustible materials [e.g. empty boxes and wooden pallets].
Recent events (3)
  • — F (S) $4000
  • — C (S) $8806
  • — Z (S) $8806

View United States Postal Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345755185.