FAIRFIELD, OH —
OSHA Inspection: PANELMATIC CINCINNATI, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PANELMATIC CINCINNATI, INC. in 258 DONALD DRIVE, FAIRFIELD, OH 45014 (NAICS 335313). OSHA activity number 345757595.
Where did this inspection happen?
- Establishment
- PANELMATIC CINCINNATI, INC.
- Site address
- 258 DONALD DRIVE
- City
- FAIRFIELD
- State
- OH
- ZIP
- 45014
- Mailing
- 258 DONALD DRIVE, FAIRFIELD, OH 45014
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335313
- Employees
- 14
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.36 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. (a) On or about February 2, 2022 , doors marked as exits were opened with knobs instead of panic bars, such as but not limited to the two doors in shipping by the loading dock, the door at the rear of the building in finishing, and the set of double doors in fabrication by the employee parking lot.
Recent events (1)
- — Z (O) $0
1910.101 B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
P249
General-duty citation text
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-2015, which is incorporated by reference as specified in Sec. 1910.6. "All compressed gas cylinders in service or in storage at user locations shall be secured to prevent falling or rolling. " (a) On or about February 2, 2022, a cylinder of propylene was not secured to prevent falling and rolling, in the area of the welding cart.
Recent events (1)
- — Z (O) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. (a) The employer had not completed the required certification that a workplace hazard assessment had been performed.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 335313)
POLK, PA—2026-06-25
VOYTEN ELECTRIC AND ELECTRONICS, INC.
REMLAP, AL—2026-05-28
SOUTHEASTERN MANUFACTURING INC
BEAVER, PA—2026-03-04
EATON CORPORATION
BEAVER, PA—2026-03-04
EATON CORPORATION
COVERT, MI—2026-02-09
SIEMENS ENERGY, INC.
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345757595.