Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PANELMATIC CINCINNATI, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PANELMATIC CINCINNATI, INC. in 258 DONALD DRIVE, FAIRFIELD, OH 45014 (NAICS 335313). OSHA activity number 345757595.

Watch Panelmatic Cincinnati, INC. — free Get an email when a new federal OSHA severe-injury report for Panelmatic Cincinnati, INC. is published. One employer, no account, unsubscribe in one click.
Site address
258 DONALD DRIVE
City
FAIRFIELD
State
OH
ZIP
45014
Mailing
258 DONALD DRIVE, FAIRFIELD, OH 45014
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335313
Employees
14
Ownership type
A

3 citations on file for this inspection.

1910.36 D01

Other-than-serious 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.36(d)(1):  Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge.  A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.  (a)  On or about February 2, 2022 , doors marked as exits were opened with knobs instead of panic bars, such as but not limited to the two doors in shipping by the loading dock,  the door at the rear of the building in finishing, and the set of double doors in fabrication by the employee parking lot.
Recent events (1)
  • — Z (O) $0

1910.101 B

Other-than-serious 1 instance 14 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances P249

29 CFR  1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-2015, which is incorporated by reference as specified in Sec. 1910.6.   "All compressed gas cylinders in service or in storage at user locations shall be secured to prevent falling or rolling. "   (a)  On or about February 2, 2022, a cylinder of propylene was not secured to prevent falling and rolling, in the area of the welding cart.
Recent events (1)
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.132(d)(2):  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  (a)  The employer had not completed the required certification that a workplace hazard assessment had been performed.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345757595.