GAINESVILLE, GA —
OSHA Inspection: FOX FACTORY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOX FACTORY, INC. in 2513 WEST PARK DRIVE, GAINESVILLE, GA 30504 (NAICS 336390). OSHA activity number 345757785.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FOX FACTORY, INC.
- Site address
- 2513 WEST PARK DRIVE
- City
- GAINESVILLE
- State
- GA
- ZIP
- 30504
- Mailing
- 2513 WEST PARK DRIVE, GAINESVILLE, GA 30504
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336390
- Employees
- 1050
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.242 B
- Issued
- Jun 16, 2022
- Penalty
- Initial $10,360 · Current $5,180 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.: (a) At Horizontal band saw #1, on or about February 1, 2022, employees using compressed air at approximately 110 P.S.I to clean equipment and debris in work area was exposed to a struck-by hazard.
Recent events (2)
- — I (S) $5180
- — Z (S) $10360
1910.147 C05 II
- Issued
- Jun 16, 2022
- Abate by
- Jul 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(ii):Lockout devices and tagout devices were not singularly identified: a) At the Okuma MB 4000H S/N 215706, on or about February 1, 2022 an employee was observed using locks and tags that were not marked to indicate who applied the devices was exposed to an electrical shock and caught-in hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Jun 16, 2022
- Abate by
- Jul 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) At the Okuma MB 4000H S/N 215706, on or about February 1, 2022, an employee observed performing servicing and maintenance was exposed to electrical hazards at approximately 240-480 volts where the periodic inspection, not limited to the Okuma MB 400H CNC, had not been conducted since 2019.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) in Cells 23A & 23B, on or about February 1, 2022, workers were observed exposed to 120V electrical hazards where the employer used eight (8) plastic electrical quad-outlet box on the end of a flexible cable as a pendant and not permanently affixed per manufacturer's specifications, at each workstation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FOX Factory, INC.