TAMUNING, GU ·
OSHA Inspection: SUMITOMO MITSUI CONSTRUCTION CO. LTD.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUMITOMO MITSUI CONSTRUCTION CO. LTD. in CORNER OF RT1 AND HWY 10A, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 345762470.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUMITOMO MITSUI CONSTRUCTION CO. LTD.
- Site address
- CORNER OF RT1 AND HWY 10A
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- PO BOX 9670, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 14
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 C02
- Issued
- Apr 25, 2022
- Abate by
- May 12, 2022
- Penalty
- Initial $7,044 · Current $4,931 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: Along the retaining wall: Scaffolding used to put up wall forms did not have base plates or firm foundations. Employees were exposed to fall hazards.
Recent events (2)
- · I (S) $4930.8
- · Z (S) $7044
1926.451 E04 III
- Issued
- Apr 25, 2022
- Abate by
- May 12, 2022
- Penalty
- Initial $10,566 · Current $7,396 Reduced
General-duty citation text
29 CFR 1926.451(e)(4)(iii): Handrails, and top rails that serve as handrails, shall provide an adequate handhold for employees grasping them to avoid falling. a. The access area scaffold from the basement to main floor: The stair access scaffold used to provide access from the basement to the main floor did not have handrails or top rails. Employees were exposed to fall hazards. b. The access area scaffold from the main floor to the top floor: The stair access scaffold used to provide access from the main floor to the top floor did not have handrails or top rails. Employees were exposed to fall hazards.
Recent events (2)
- · I (S) $7396.2
- · Z (S) $10566
1926.451 E04 VIII
- Issued
- Apr 25, 2022
- Abate by
- May 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(4)(viii): A landing platform at least 18 inches wide and at least 18 inches wide was not provided at each level. a. The access area scaffold from the basement to main floor: The stair access scaffold used to provide access from the basement to the main floor did not have landing platforms. Employees were exposed to fall hazards. b. The access area scaffold from the main floor to the top floor: The stair access scaffold used to provide access from the main floor to the top floor did not have landing platforms. Employees were exposed to fall hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F07
- Issued
- Apr 25, 2022
- Abate by
- May 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. The access area scaffold from the basement to main floor: The stair access scaffold used to provide access from the basement to the main floor was not erected under the supervision of a competent person. Employees were exposed to fall hazards. b. The access area scaffold from the main floor to the top floor: The stair access scaffold used to provide access from the main floor to the top floor was not erected under the supervision of a competent person. Employees were exposed to fall hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.25 A
- Issued
- Apr 25, 2022
- Abate by
- May 5, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. a. At the southeast main level entrance: Construction debris and garbage were accumulated around the access door. Employees were exposed to slip, trip, and fall hazards. b. At the northeast main level entrance: Construction debris and garbage were accumulated around the access door. Employees were exposed to slip, trip, and fall hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Sumitomo Mitsui Construction CO. LTD.
View Sumitomo Mitsui Construction CO. LTD.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345762470.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.