Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & H CRATES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of M & H CRATES, INC. in 4022 FM 347 NORTH, JACKSONVILLE, TX 75766 (NAICS 321920). OSHA activity number 345768790.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & H Crates, INC. — free Get an email when a new federal OSHA severe-injury report for M & H Crates, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
M & H CRATES, INC.
Site address
4022 FM 347 NORTH
City
JACKSONVILLE
State
TX
ZIP
75766
Mailing
4022 FM 347 NORTH, JACKSONVILLE, TX 75766
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
100
Ownership type
A

12 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 3 instances 75 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.22(a)(1):  The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces:  On or about March 3, 2022, and times prior thereto, pour housekeeping throughout the saw mill created unsafe working conditions for employees:  Instance a:  There was an accumulation of saw dust in saw mill 1;  Instance b:  There was an accumulation  of saw dust in gang saw line; and  instance c:  There was an accumulation of saw dust in the copper mill building.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.133 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.133(a)(1):  The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a)  On or about February  8, 2022, and at times there after, employees working with saw mill production did not use safety glasses,  exposing employees to eye and/or face injuries.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.147 C07 I A

Serious Gravity 10 1 instance 10 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.147(c)(7)(i)(A):  Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  On or about February 8, 2022 and times prior to and after, the employer did not ensure that authorized employees who perform maintenance on equipment with multiple energy sources received training on the hazardous energy sources of that equipment.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.147 C07 I B

Serious Gravity 10 1 instance 25 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(B): Each affected employee was not instructed in the purpose and use of the energy control procedure:   On or about February 8, 2022, and times prior to and after, affected employees had not been trained to recognize the need for energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 C

Serious Gravity 10 1 instance 25 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.176(c):  Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion, or pest harborage:  a)  On or about March 3, 2022 and times prior thereto, the employer did not ensure areas were kept free from accumulation of materials and debris that constituted a hazard.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.219 F03

Serious Gravity 10 1 instance 5 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.219(f)(3):  Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed:  a)  On or about March 3, 2022, and times prior thereto, employees were exposed to amputation hazards while walking past unguarded chain and pulley.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.303 B07 I

Serious Gravity 10 3 instances 75 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  a)  On or about March 3, 2022, where employees were exposed to electrical hazards while working around open box in gang saw line building;
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.303 G01

Serious Gravity 10 1 instance 25 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.   a)  On or about March 3, and times prior to, where electrical panels were blocked and did not allow sufficient space for employees to have access to in case of an emergency or maintenance.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:  a) On or about March 3, 2022 where employees where exposed to electrical hazards while working around opened electrical boxes at the copper mill building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 10 1 instance 25 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.305(b)(2)(i):  All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose. If metal covers are used, they will be grounded. In completed installations, each outlet box will have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass will be provided with bushings designed for the purpose or will have smooth, well-rounded surfaces on which the cords may bear.  a)  On or about March 3, 2022, where employees were exposed to electrical hazards while working near open cabinets in saw mill 1.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.305 G02 III

Serious Gravity 10 1 instance 25 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $11,167 · Current $5,208 Reduced
29 CFR  1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:  a) On or about March 3, 2022, and times prior thereto, in saw mill 1, where electrical plug wiring coming from the electrical panel were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.
Recent events (2)
  • — I (S) $5208
  • — Z (S) $11167

1910.147 C04 I

Willful Gravity 10 1 instance 10 exposed
Issued
Aug 3, 2022
Abate by
Aug 29, 2022
Penalty
Initial $127,624 · Current $90,005 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   The employer did not develop and/or document and/or utilize energy control procedures for employees who perform maintenance work on equipment and machinery:   a)  On or about March 2, 2022, and times prior thereto, where employees changed a blade in the gang line/saw building and were exposed to amputation hazards;  b)  On or about March 3, 2022, and times prior thereto, where employees changed the cylinder on the PC-2 pallet nailer machine (nailer building) and were exposed to amputation hazards;  c)  On or about March 9, 2022, and times prior thereto, where employees changed a part on the PC-2 pallet nailer machine that makes the chain walk (nailer building) and were exposed to amputation hazards.  Employees are exposed to hazards such as but not limited to amputations, struck-by and crushed-by hazards. Energy sources consist of hydraulic, pneumatic, mechanical and stored.
Recent events (2)
  • — I (W) $90004.8
  • — Z (W) $127624

View M & H Crates, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345768790.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.