Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHWASTE DISPOSAL, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SOUTHWASTE DISPOSAL, LLC in 6407 HURST ST., HOUSTON, TX 77008 (NAICS 562219). OSHA activity number 345771471.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southwaste Disposal, LLC — free Get an email when a new federal OSHA severe-injury report for Southwaste Disposal, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6407 HURST ST.
City
HOUSTON
State
TX
ZIP
77008
Mailing
6407 HURST ST., HOUSTON, TX 77008
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562219
Employees
30
Ownership type
A

5 citations on file for this inspection.

1910.22 A03

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2022
Abate by
Mar 17, 2022
Penalty
Initial $5,801 · Current $3,481 Reduced
29 CFR  1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice:  On or about February 8, 2022, on the east side of the facility, employees were exposed checking water levels and PH in the 30 foot water tank without access and egress to the tank being free of hazards, in that there were loose stair treads and floor panels on the catwalk flexed significantly when walked on.
Recent events (2)
  • — I (S) $3480.6
  • — Z (S) $5801

1910.22 A02

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2022
Abate by
Mar 17, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided:  On or about February 8, 2022, in the Press Room, employees were exposed to slip and fall hazards while using a catwalk covered in wet plywood without maintaining drainage for the wet process.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2022
Abate by
Mar 17, 2022
Penalty
Initial $7,252 · Current $4,351 Reduced
29 CFR  1910.28(b)(1)(i):29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  On or about February 8, 2022, in the Press Room, employees were exposed to a fall hazard of more than 4 feet while using a catwalk without guardrails or any other fall protective system.
Recent events (2)
  • — I (S) $4351.2
  • — Z (S) $7252

1910.151 C

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2022
Abate by
Mar 17, 2022
Penalty
Initial $5,801 · Current $3,481 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  On or about February 8, 2022, and at times prior thereto, employees working around the Press Room area were exposed to chemical hazards from bulk stored and batch mixed lime in the work area, without having access to an operable eyewash and shower station.
Recent events (2)
  • — I (S) $3480.6
  • — Z (S) $5801

1910.305 G01 IV A

Other-than-serious 1 instance 4 exposed
Issued
Feb 28, 2022
Abate by
Mar 17, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about February 8, 2022,  on the east side of the Press Room, an extension cord was used to permanently provide fixed wiring to:  a. area light without permanent hard wired fixtures  b. flocculant mixing tank pump
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Southwaste Disposal, LLC's full OSHA safety record →