Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.F. FREDERICKS AERO LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J.F. FREDERICKS AERO LLC. in 206 NEWINGTON AVENUE, NEW BRITAIN, CT 06051 (NAICS 336412). OSHA activity number 345772834.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.F. Fredericks Aero LLC. — free Get an email when a new federal OSHA severe-injury report for J.F. Fredericks Aero LLC. is published. One employer, no account, unsubscribe in one click.
Site address
206 NEWINGTON AVENUE
City
NEW BRITAIN
State
CT
ZIP
06051
Mailing
206 NEWINGTON AVENUE, NEW BRITAIN, CT 06051
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336412
Employees
23
Ownership type
A

5 citations on file for this inspection.

1910.22 D02

Serious Gravity 1 1 instance 20 exposed
Issued
Jun 6, 2022
Abate by
Jul 25, 2022
Penalty
Initial $2,113 · Current $1,057 Reduced
29 CFR  1910.22(d)(2):  The employer did not ensure that hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again. The employer did not ensure that if the correction or repair cannot be made immediately, the hazard is guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired:  Break Room:  On, or about, February 7, 2022, water that had leaked into the building through the roof was present on the floor.  Sufficient procedures had not been implemented to remove the water in a timely fashion and the wet portion of the floor had not been marked with signs or other effective way to alert employees of the wet floor conditions.
Recent events (2)
  • — I (S) $1056.5
  • — Z (S) $2113

1910.212 A01

Serious Gravity 5 6 instances 5 exposed
Issued
Jun 6, 2022
Abate by
Jul 25, 2022
Penalty
Initial $3,522 · Current $1,761 Reduced
29 CFR  1910.212(a)(1):  Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts and chips:  Production Area:  On, or about, February 7, 2022, access doors on the following CNC machines were not locked/interlocked during the automatic mode:  A.	Machine 104, Doosan V850.   B.	Machine 22,  Doosan V850. C.	Machine 1, Nakamura-Tome SC-450. D.	Machine 55, Nakamura-Tome SC-300. E.	Machine 89, Nakamura-Tome SC-300. F.	Machine 97, Puma 300c.
Recent events (2)
  • — I (S) $1761
  • — Z (S) $3522

1904.41 A02

Other-than-serious 1 instance 23 exposed
Issued
Jun 6, 2022
Abate by
Jul 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1904.41(a)(2):  The establishment had 20 or more but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified as an industry listed in appendix A to subpart E of this part, but did not electronically submit information from OSHA 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee.  The employer did not submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form:  (a) J.F. Fredericks Aero LLC, 206 Newington Avenue, New Britain, Connecticut:  On or about June 3, 2022, and times prior thereto, the employer failed to electronically submit information from their OSHA Form 300A Summary of Work-Related Injuries and Illnesses for 2021 or equivalent on or before March 2, 2022.  The establishment employed 23 employees and was classified under NAICS 336412 during calendar year 2021.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 10 exposed
Issued
Jun 6, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii):  Unused openings in boxes, cabinets, or fittings were not effectively closed:  Production Area:  On, or about, February 7, 2022, a knockout was left uncovered on the side of the GE step down transformer located near the sump hole.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 2 instances 10 exposed
Issued
Jun 6, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i):  Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  Production Area:  On, or about, February 7, 2022, covers were not provided on the following:  A.	Ceiling mounted raceway above the main panels. B.	Two junction boxes mounted above the Auto Crib.